JRC JMA-5312-6HS Installation Manual page 48

Marine radar equipment
Hide thumbs Also See for JMA-5312-6HS:
Table of Contents

Advertisement

All manuals and user guides at all-guides.com
Speed log switch setting
1.
This radar's compatible standard speed logs are the following eight types:
Pulse type: 800 pulses/NM, 400 pulses/NM, 200 pulses/NM, 100 pulses/NM
Synchro type: 360X/NM, 180X/NM, 90X/NM, 30X/NM
Set the S5 GYRO/LOG select switch according to the S5 setting table.
2.
Connect the speed log signal input line to TB20. To do so, for the pulse type, connect the
line to the PULSE side and, for the synchro type, connect the line to the SYNC side. With
respect to the positive (+) and negative (-) sides, when the pulse type is selected, the negative
(-) side is the ground.
2) Installing the gyro I/F unit
Install the gyro I/F unit in the radar process unit according to the procedures below:
(1) Remove the radar process unit cabinet cover, loosen the screws that mount the terminal board to the
cabinet, and remove the terminal board from the radar process unit cabinet.
(2) Combine the removed terminal board with the gyro I/F unit.