Other Components continued: 
At this point you can access 
the primary air control 
damper assembly, 
thermostatic actuator 
assembly and the damper 
release lever.  Although these 
shouldn't need to be replaced, 
they can be easily.  The 
primary air control damper
assembly can be replaced by 
removing the small spring 
handle from the front of the 
unit, then sliding the assembly out.  Replace by sliding the new assembly through the same hole 
and the rod through the front of the stove.  Replace the spring handle.  The thermostatic
actuator assembly can be replaced by using a 5/16" socket to remove the two screws that hold 
the assembly. Install the new assembly using the same two screws.  The damper release lever 
can be replaced by removing the ½" bolt.  When reinstalling the damper be sure it is installed 
the same as when removed. 
 
Blower:  The wood stove was also designed for use with a convection blower for additional heat 
circulation.  The stove is constructed with side convection channels which allow the room air 
blower to pick up heat from the hottest regions of the stove and transfer it into the home.  The 
mounting screws for the blower are installed into the rear convection channel at the factory; 
mounting the blower only requires a 5/16" open end or socket wrench to remove these screws 
and install the blower.   
When routing the power cord, take care to keep away from hot areas of the unit and remember 
that this blower is for use only with the stove.  Please see the diagram below for clarification on 
the room air blower installation.   
This unit can use the AC‐16 (which comes standard with the unit) or the AC‐30 upgrade blower. 
Both are installed using the four factory installed 5/16" screws. 
The optional heat circulation blower on this stove requires periodic lubrication; this lubrication should be performed 
no less than every three months of normal operation.  To properly lubricate the blower, use an eye dropper or 
similar dispensing device to drip 5‐7 droplets of SAE 20 oil into the oil port on the side of the blower motor 
 
 
 
 
 
 
 
 
 
 
OPTIONAL ACCESSORIES  
(4) 5/16" head, self‐tapping 
screws (pre‐installed in unit). 
Warning: Disconnect power 
from fan before installation. 