England's Stove Works Smartstove 50-SHSSW02 Installation & Operation Manual page 13

Hide thumbs Also See for Smartstove 50-SHSSW02:
Table of Contents

Advertisement

Available languages

Available languages

 
 
Approved Venting Method 3: Internal or External Masonry Chimney System 
 
 
 
 
 
 
 
 
Chimney liner cross‐sectional 
area (Length x Width) must be 
no larger than twice the cross‐ 
sectional area of the flue collar 
(2 x 28.27 in
= 56.55 in
chimney liner is larger than 
2
56.55 in
, relining with a 5.5" 
or 6.0" liner is required 
 
 
Masonry Thimble with 
proper clearance to 
combustibles 
 
Follow the rules listed above concerning maximum permissible flue liner size; installing this unit on masonry 
chimneys exceeding 56.55 
performance. 
Use three sheet metal screws at each single wall chimney connector joint (check manufacturer's 
recommendations when double wall chimney connector is used). 
Drill three holes in the flue collar of the unit and attach the chimney connector to the unit using sheet metal 
screws (holes should be pre‐drilled in flue collar from factory). 
Avoid numerous elbows and excessive horizontal runs as both will lead to poor draft and increased creosote 
accumulation.   Horizontal runs of chimney connector must never exceed 4.0 ft. and the overall length of the 
chimney connector must not exceed 8.0 ft. 
A tight seal at the thimble is crucial for proper unit performance and to create a safe installation.  Use the proper 
adapter designed for connecting single or double wall chimney connector to a masonry thimble. 
Have existing masonry chimneys inspected for safety and proper clearances to combustibles before putting them 
into service; a qualified chimney sweep can perform this inspection. 
External masonry chimneys often suffer cold downdrafts and poor draft performance even when they meet the 
cross‐sectional area rules.  In this case, a 6.0" insulated liner may be necessary. 
 
 
 
Please Note: Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans 
for each individual installation.  Please follow all venting system requirements, maintain the required clearances to 
combustibles, and follow all local codes. 
INSTALLATION 
2
).  If 
in
in cross‐sectional area will result in decreased draft and the potential for poor unit 
10 ft. 
The 10‐3‐2 Rule: The chimney system 
must terminate 3.0 ft. above the point 
where its centerline passes through the 
roof AND the chimney must terminate 
2.0 ft. above any part of the dwelling 
within a 10 ft. radius of the chimney. 
 
 
 
Chimney Connector 
(Single or Double Wall) 
 
Ash Cleanouts must 
have an airtight seal to 
prevent weak draft. 
Page | 13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartstove 15-ssw02Smartstove 50-trssw02

Table of Contents