Main circuit terminal specifications
Three-phase 400V class
FR-D740-012 to 080
Jumper
N/- P/+
Screw size (M4)
R/L1 S/L2 T/L3
PR
Screw size
(M4)
Power supply
Single-phase 200V class
FR-D720S-008 to 042
Screw size (M3.5)
N/-
P/+
PR
R/L1 S/L2
Screw size
IM
(M3.5)
Power supply
Motor
NOTE
Make sure the power cables are connected to the R/L1, S/L2, T/L3. (Phase need not be matched.) Never connect the
power cable to the U, V, W of the inverter. Doing so will damage the inverter.
Connect the motor to U, V, W. Turning on the forward rotation switch (signal) at this time rotates the motor
counterclockwise when viewed from the load shaft.