Function assignment of external terminal and control
(1) Input terminal function assignment
Using Pr. 178 to Pr. 182, set the functions of the input terminals.
Refer to the following table and set the parameters:
Setting
Signal
Pr. 59 = 0 (initial value)
0
RL
Pr. 59 ≠ 0 ∗1
Pr. 59 = 0 (initial value)
1
RM
Pr. 59 ≠ 0 ∗1
Pr. 59 = 0 (initial value)
2
RH
Pr. 59 ≠ 0 ∗1
3
RT
Second function selection
4
AU
Terminal 4 input selection
5
JOG
Jog operation selection
External thermal relay input ∗2
7
OH
15-speed selection (combination with three speeds RL, RM,
8
REX
RH)
10
X10
Inverter run enable signal (FR-HC, FR-CV connection)
12
X12
PU operation external interlock
14
X14
PID control valid terminal
PU-external operation switchover (turning ON X16 selects
16
X16
external operation)
18
X18
V/F switchover (V/F control is exercised when X18 is ON)
24
MRS
Output stop
25
STOP
Start self-holding selection
Forward rotation command (assigned to STF terminal (Pr. 178)
60
STF
only)
Reverse rotation command (assigned to STR terminal (Pr. 179)
61
STR
only)
62
RES
Inverter reset
PU/NET operation switchover (turning ON X65 selects PU
65
X65
operation)
External/NET operation switchover (turning ON X66 selects
66
X66
NET operation)
Command source switchover (turning ON X67 makes Pr. 338
67
X67
and Pr. 339 commands valid)
9999
No function
∗1
When Pr. 59 Remote function selection ≠ "0", the functions of the RL, RM and RH signals are changed as given in the table.
∗2
The OH signal turns ON when the relay contact "opens".
NOTE
Changing the terminal assignment using Pr.178 to Pr.182 (input terminal function selection) may affect the other functions.
Make setting after confirming the function of each terminal.
One function can be assigned to two or more terminals. In this case, the terminal inputs are ORed.
The priorities of the speed commands are in order of jog > multi-speed setting (RH, RM, RL, REX) > PID (X14).
When the X10 signal (FR-HC, FR-CV connection-inverter operation enable signal) is not set or when the PU operation
external interlock (X12) signal is not assigned with Pr.79 Operation mode selection set to "7", the MRS signal shares this
function.
Same signal is used to assign multi-speed (7th speed) and remote setting. They cannot be set individually.
(Same signal is used since multi-speed (7th speed) setting and remote setting are not used to set speed at the same
time.)
When V/F control is selected by V/F switchover (X18 signal), second function is also selected at the same time.
Control between V/F and General-purpose magnetic flux can not be switched during operation. In case control is
switched between V/F and General-purpose magnetic flux, only second function is selected.
Turning the AU signal ON makes terminal 2 (voltage input) invalid.
(2) Response time of each signal
The response time of the X10 signal and MRS signal is within 2ms.
The response time of other signals is within 20ms.
114
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Function
Related Parameters
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27
Low-speed operation command
Pr.232 to Pr.239
Remote setting (setting clear)
Pr. 59
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Middle-speed operation command
Pr. 232 to Pr. 239
Remote setting (deceleration)
Pr. 59
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
High-speed operation command
Pr. 232 to Pr. 239
Remote setting (acceleration)
Pr. 59
Pr. 44 to Pr. 51
Pr. 267
Pr. 15, Pr. 16
Pr. 9
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Pr. 30, Pr. 70
Pr. 79
Pr. 127 to Pr. 134
Pr. 79, Pr. 340
Pr. 80
Pr. 17
Pr. 79, Pr. 340
Pr. 79, Pr. 340
Pr. 338, Pr. 339
Refer to
Page
89
93
89
93
89
93
116
150
91
100
89
110
165
212
172
75, 105
115
117
117
117
173
173
176