Platform Controls; Controllers - Terex Genie Z452513A-48153 Service And Repair Manual

Table of Contents

Advertisement

Service and Repair Manual

Platform Controls

1-1

Controllers

The drive joystick is connected to the drive motor
controller located under the non-steer end drive
chassis cover. The drive motor controller can also
recognize machine drive malfunctions and display
controller fault codes by flashing an LED at the
ground controls. Refer to the Fault Codes section
for a list of fault codes and additional information.
There are no adjustments needed on the drive
joystick controller. For further information or
assistance, consult the Genie Product Support.
1 boom function speed controller
2 drive joystick
14
Z®-45/25 Bi-Energy • Z®-45/25J Bi-Energy
Boom Function Speed Controller
Adjustments
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
Note: Do not adjust the boom function speed
controller unless the static battery supply voltage is
above 24V DC.
1
Turn the key switch to platform controls and
pull out the red Emergency Stop button to the
on position at both the ground and platform
controls.
2
Open the platform control box lid and locate
the boom function speed controller.
1 white/red wire to TP6
2 boom function speed controller
3 threshold trimpot
4 max out trimpot
August 2023
Part No. 1268546GT

Advertisement

Table of Contents
loading