Master Mistral Compact Manual page 9

Wind device with integrated radio receiver for 1 motor
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
WARNING
In this sheet there are contained important informations regarding form of use and
safety of installation. Respect this instructions and keep them for eventual follow-
ing consultations. The central MISTRAL COMPACT/60.001.110 is suitable for
control of a asynchronous single-phase motor powered by voltage for the move-
ment of awnings or similar, every other use is inappropriate and prohibited.
1. TECHNICAL DATA (in reference of 20°C temperature)
- Power Supply:
- Motors Power Maximum:
- Temperature of exercise:
- Integrated Sensors:
- Wind Threshold:
- Radio Frequency:
- Radio Memorizable codes:
2. NOTES ABOUT RADIO SYSTEMS
- Radio installation cannot be used where there is a high disturbing factor (for
examples: near police stations, airports, banks and hospitals). However it is
advisable that a technician could see the place before installing any kind of radio
system in order to verify the possibility of a radio installation.
- Radio devices can be used only if any possible interferences or malfunction of
the transmitter or of the receiver are not a factor of risk, or if the factor of risk is
canceled by security system.
- The presence of radio devices working at the same frequency of transmission
(for example allarms and earphones) could interfere with radio receiver of central
unit cutting down the capacity of the transmitter and restricting the full function-
ality of the system.
3. ELETTRIC CONNECTIONS
CABLES ON THE FUND
OF THE CONTAINER
- The product must to be installed by technical qualify staff to respect all the rules
and laws in forces on the territory.
- The module is subject by dangerous electric voltage. Make connections without
power supply.
- Work with caution on the product, use suitable tools.
- Verify that the line of supply doesn't result from circuit for lighting.
- The line of supply has to be protect from a suitable magnetothermic or differen-
tial device.
- In case of many radio installations in the same system, the distance between
them doesn't have to be less than 1,5 mt.
- Do not install the module near metallic surface.
MISTRAL COMPACT_rev00
SCREW
120 or 230 Vac, 50/60 Hz
10 to @ 230 Vac
from –20 to +70 °C
wind
from 10 Km/h to 35 Km/h
433,92 MHz
15
CABLE
D1
S1
C
M
POWER SUPPLY
120 - 230 Vac
N
L
50/60 Hz
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

60.001.110

Table of Contents