Once the reader is wired into the system, the module needs to be addressed. Unlike most
NetworX expanders, the address of any particular reader is determined by itself after installation
is complete. Follow the procedures outlined under the section "PROGRAMMING". When prompted
to enter the module device number, a card must be scanned at the reader to initiate addressing
(one short beep). When completed (1-2 seconds), the reader will beep back its address (long
beeps). Refer to Table 0-1 that follows for possible addresses.
Table 0-1
USING THE LED KEYPAD
Only NX-13xx keypad series allow to program user cards.
Entering the Program Mode
[
Go To Program Code
Factory Default is
Entering the Module Address
Scan a card.
#
(example only)
NX-1701E Installation manual
ADDRESSING
Beeps
Address
1
113
2
114
3
115
4
116
5
117
6
118
7
119
8
120
PROGRAMMING
ACTION
]
Page 5
Beeps
Address
9
121
10
122
11
123
12
124
13
125
14
126
15
127
RESULT
Enters the Program Mode.
Stay, Chime, Exit, Bypass & Cancel LEDS will flash.
If the "Go To Program Code" is valid, the "Service"
LED will flash and the 5 function LEDs will illuminate
steady. You are now in the Program Mode and
ready to select the module address.
The card reader will address itself.
Enters the module address. Refer to Table 0-1 on
page 5 for the address assigned by the card reader
module itself.
The Armed LED will illuminate while it is waiting for a
programming location to be entered.
Scan: To
"present" or
pass a card or
FOB within
sensing range of
the card reader
module.
31/01/05