Interlogix NetworX NX-1701E Installation Manual page 18

Proximity card reader
Table of Contents

Advertisement

LOC
PG
243
12
PROGRAMMING THE ZONES
Seg 1
Seg 2
244
13
READER TIMES
Seg 1
Seg 2
Seg 3
Seg 4
245
13
RESET THE READER ADDRESS
Entering a "0" will reset and cause the reader to
cease functioning.
246
13
PROGRAMMING THE ACCESS OPTIONS
Seg 1
Seg 2
Seg 3
247
14
OPENING TIME FOR SCHEDULE 1
Seg 1
Seg 2
248
14
CLOSING TIME FOR SCHEDULE 1
Seg 1
Seg 2
NX-1701E Installation manual
DESCRIPTION
Door Shunt Zone
Request to Exit (RTE)
Scan Time (1/100 seconds)
Relay Active Time (seconds)
Door Fault Warning Time (seconds)
Door Fault Alarm Time (seconds)
DOOR OPTIONS
1 = "On" if locking mechanism is a Maglock or Drop Bolt.
2 = "On" if access is allowed regardless of Armed status of the system.
3 = "On" if the door is not to be latched unlocked during an open schedule.
4 = "On" if onboard open collector output only triggers during an open schedule.
5 = "On" if onboard open collector output only triggers during a close schedule.
6 = "On" if Forced Entry Alarm is logged.
7 = "On" if access allowed without an RTE.
8 = "On" if relay operates normally during off-schedule
SCHEDULES FOR ONBOARD OPEN COLLECTOR OUTPUT
1 = "On" if driver follows Schedule 1.
2 = "On" if driver follows Schedule 2.
3 = "On" if driver follows Schedule 3.
4 = "On" if driver follows Schedule 4.
5 = "On" if driver follows Schedule 5.
6 = "On" if driver follows Schedule 6.
7 = "On" if driver follows Schedule 7.
8 = "On" if driver follows Schedule 8.
MORE DOOR OPTIONS
1 = "On" if egress input is to be disabled
2 = Reserved
3 = Reserved
4 = Reserved
5 = Reserved
6 = Reserved
7 = Reserved
8 = Reserved
Hour of Opening Time (24-hr format)
Minutes after Hour of Opening
Hour of Closing Time (24-hr format)
Minutes after Hour of Closing
Page 18
DEFAULT
0 = Disabled
0 = Disabled
100 = 1 second
10 = 10 seconds
30 = 30 seconds
0 = 0 seconds
8 = 8 AM
0
20 = 8 PM
0
YOUR DATA