SCAN METHODS: Legacy mode is default. Alternative mode is shown below in brackets { }.
Refer to Location 242 Segment 1 on page 11, and the Glossary on page 23 for explanation.
Location 0
Programming the Scan Functions
(3 segments of binary data) Location 0 is used to select the particular function(s) that are activated when a card is
scanned. More than one function may be selected. If more than one function is selected, they will execute in order
from function 1 to function 8.
Functions 1-6 will be performed based on the user's authority as programmed by the [ ] [6]
function (refer to keypad user manual).
Segment 1
Single Scan Function {Single Beep}
Program the functions that are performed when a card is scanned {one beep}.
"On" to send Code Entry function to the control panel.
LED1 -
"On" to activate the Armed Away mode.
LED2 -
"On" to activate the Armed Stay mode.
LED3 -
"On" to send the Disarm function to the control panel.
LED4 -
"On" to send Auxiliary Function #1 to the control panel.
LED5 -
"On" to send Auxiliary Function #2 to the control panel.
LED6 -
"On" to broadcast an X-10 function (see Location 241 for programming).
LED7 -
"On" to send a Request To Exit (RTE); and activate the onboard open collector output. (Default
LED8 -
is "On")
RTE to be sent.
Segment 2
Double Scan Function {Double Beep}
Program the functions that are performed when a card is scanned twice within the 2 Scan Hold Time {two beeps}.
Location 244, Segment 1 programs the length of time between beeps. The descriptions of the options are the same
as for Single Beep Scan Function. Default is 1.
Segment 3
Single Scan Hold Function {Triple Beep}
Program the functions that are performed when a card is scanned and held at the reader for the duration of the 2
Scan Hold Time {three beeps}. Location 244, Segment 1 programs the length of time between beeps. The descriptions
of the options are the same as for Single Beep Scan Function. Default is 1.
Locations 1 - 240

Location 241 Programming the X-10 Address for the Scan Functions

(5 segments of numerical data)
Segment 1
Program a number from 0 -15 to represent the corresponding X-10 Module Number from the following table.
Default is 0.
Module
Seg 1
NX-1701E Installation manual

PROGRAMMING LOCATIONS

Location 243, Segment 2 must be programmed with a valid zone number for the
Reserved
1
2
3
4
5
0
1
2
3
4
Page 10
6
7
8
9 10 11 12 13 14 15 16
5
6
7
8
9 10 11 12 13 14 15
31/01/05