MIDI Implementation
● Universal System Exclusive message
❍Identity Request
Status
Data Byte
F0H
7EH,Dev,06H,01H
Byte
Description
F0H
Status of System Exclusive Message
7EH
Universal System Exclusive message Non Real-time header
Dev
Device ID (or 7FH)
06H
General Information (sub-ID #1)
01H
Identify Request (sub-ID #2)
F7H
EOX (End of System Exclusive message)
The message is used to request the particular information of the VS-2000.
The VS-2000 does not transmit the message.
If the VS-2000 received the message and the device ID of the message is same as its device.
ID or 7FH, the VS-2000 transmits the following Identify Reply message.
❍Identity Reply
Status
Data Byte
F0H
7EH,Dev,06H,02H,41H,mmH,mmH,
00H,00H,00H,00H,ssH,ssH
Byte
Description
F0H
Status of System Exclusive Message
7EH
Universal System Exclusive Non Real-time Header
Dev
Device ID
06H
General Information (sub-ID #1)
02H
Identify Request (sub-ID #2)
41H
Manufacturer ID (Roland)
mmH mmH
Device Family Code (VS-2000)
00H 00H
Device Family No.
00H
00H
ssH ssH
Software Revision Level
F7H
EOX (End of System Exclusive message)
When VS-2000, the value of the device family code is 70H 01H.
❍MIDI Time Code
Status
Data Byte
F0H
7EH,Dev,01H,01H,hr,mn,sc,fr F7H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive Real-time Header
Dev
Device ID
01H
MIDI Time Code
01H
MIDI Time Code Full Message
hr
hr Type/Hour(0yyzzzzz)
yy: Time Code Type
0=24 Frame/Sec
1=25 Frame/Sec
2=30 Frame/Sec (Drop)
3=30 Frame/Sec (Non-Drop)
mn Minutes (0–59)
sc
Second (0–59)
fr
Frame (0–59)
F7H
EOX (End of System Exclusive message)
❍MIDI Machine Control Commands
Status
Data Byte
F0H
FH,Dev,06H,aaH, ..., bbH
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive Real-time Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
aaH
Command
:
:
bbH
Command
F7H
EOX (End of System Exclusive message)
(*) see "3. MIDI Machine Control."
74
Status
F7H
Status
F7H
Status
Status
F7H
● Data Transfer (RQ1,DT1)
❍Data Request (RQ1)
Status
Data Byte
F0H
41H,Dev,00H,70H,11H,aaH,bbH,
ccH,ddH,ssH,ssH,ssH,ssh,Sum
Byte
Description
F0H
Status of System Exclusive Message
41H
Manufacturer ID (Roland)
Dev
Device ID
00H 70H
Model ID (VS-2000)
11H
Command ID (RQ1)
aaH
Address MSB
bbH
Address
ccH
Address
ddH
Address LSB
ssH
Size MSB
ssH
Size
ssH
Size
ssH
Size LSB
Sum
Check Sum
F7H
EOX (End of System Exclusive message)
This message is used to request parameters from the VS-2000.
The VS-2000 does not transmit this message.
When this message is received, the requested data will be transmitted if the following
conditions are satisfied.
1.
The address specified by RQ1 corresponds to one of the applicable parameter base
addresses of the VS-2000.
2.
The requested size is 1 or greater.
If the above conditions are satisfied, the corresponding parameters will be transmitted in
the form described in Data Set (DT1).
❍Data Set (DT1)
<Model ID = 00H 70H (VS-2000)>
Status
Data Byte
F0H
41H,Dev,00H,70H,12H,aaH,bbH, F7H
ccH,ddH, ..., eeH,Sum
Byte
Description
F0H
Status of System Exclusive Message
41H
Manufacturer ID (Roland)
Dev
Device ID
00H 70H
Model ID (VS-2000)
12H
Command ID (DT1)
aaH
Address MSB
bbH
Address
ccH
Address
ddH
Address LSB
eeH
Data
Sum
Check Sum
F7H
EOX (End of System Exclusive message)
<Model ID = 00H 36H (VE-7000)>
Status
Data Byte
F0H
41H,Dev,00H,36H,12H,aaH,bbH,F7H
ccH,ddH, ..., eeH,Sum
Byte
Description
F0H
Status of System Exclusive Message
41H
Manufacturer ID (Roland)
Dev
Device ID
00H 36H
Model ID (VE-7000)
12H
Command ID (DT1)
aaH
Address MSB
bbH
Address
ccH
Address LSB
ddH
Data
Sum
Check Sum
F7H
EOX (End of System Exclusive message)
❍The message is transmitted under the following condition.
If the device ID on the message is same as that of the receive device, and the address on the
message correspond to the specified parameter base address, the received data are stored
form the specified parameter base address.
If the interval of received messages is shorter than 25 msec, the VS-2000 can not work the
receive message procedure correctly.
Status
F7H
Status
Status