Saving And Loading Sc-8850 Settings; Transmitting The Settings Of The Sc-8850 To A Computer; Transmitting A Bulk Dump - Roland Sound Canvas SC-8850 Owner's Manual

Roland sc-8850 sound canvas: owners manual
Table of Contents

Advertisement

Saving and Loading SC-8850 Settings

Transmitting the Settings of the SC-8850
to a Computer
The SC-8850 can transmit the contents of its sound generator memory as MIDI data.
The data can be transmitted in two ways: Bulk Dump which transmits multiple pa-
rameters as a group, and Individual Data which allows parameters to be transmitted
individually. All data is transmitted as System Exclusive messages.
Use Bulk Dump when you wish to save settings of the SC-8850 on a sequencer or
computer. By transmitting a Bulk Dump, you can also set all parameters of two units
to identical settings.
By transmitting Individual Data, you can create data without having to look up in-
dividual System Exclusive messages, letting you create data more efficiently.

Transmitting a Bulk Dump

When transmitting or receiving Bulk Dump data, check the settings and procedures
on your sequencing program or sequencer.
Here we explain how to transmit data from the SC-8850.
1
Simultaneously press both the [EDIT] and
fig.10-1
2
Press [BULK] ([F2]).
3
Press
[
] or
VAR.
mit.
fig.10-2
Dump All:
Dump All-User:
Dump User Inst:
Dump User Drum:
Dump Part-A:
Dump Part-B:
Dump Part-C:
Dump Part-D:
134
PART
[
] to select the type of data you want to trans-
INST
Transmits all parameters of the SC-8850 (Including User pa-
rameters)
Transmits all parameters except User parameters (User Instru-
ment, User Drum Set) settings
Transmits User Instrument settings
Transmits User Drum settings
Transmits parameters for Part group A
Transmits parameters for Part group B
Transmits parameters for Part group C
Transmits parameters for Part group D
[
] buttons (
).
UTIL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents