Turbulator Installation - Roberts Gorden GordonRay BH-60 Installation, Operation & Service Manual

Economical unitary infrared heater
Table of Contents

Advertisement

Step 6.4 Turbulator Installation
Turbulator section 2.5'
(76.2 cm) (stainless) used in
BH-40 heaters must be in the
section of turbulator nearest
to the burner.
Description
Turbulator Adapter 2.5' (76.2 cm)
Turbulator Section 2' (61 cm)
Turbulator Section 2.5' (76.2 cm) (Stainless)
Tube
Part Number
03051503
03051504
03051505
91409XXX
Install turbulator as specified in the
"Turbulator Installation" chart below.
Turbulator is not required on the BH-125/
150/175/200.

Turbulator Installation

Model
BH-40
BH-60
BH-80
BH-100
BH-115
BH-125
BH-140
BH-150
BH-175
BH-200
SECTION 6: H
I
EATER
NSTALLATION
Tube Section
1st 10' (3 m) Section
2nd 10' (3 m) Section
2nd 10' (3 m) Section
3rd 10' (3 m) Section
3rd 10' (3 m) Section
N/A
4th 10' (3 m) Section
N/A
N/A
N/A
23 of 63