FIGURE 20: U-Tube Heater Layout Overview
LEGEND
Burner
Reflector
Tube 10' (3.0 m)
Tube 5' (1.5 m)**
Tube/Reflector
Hanger
Coupling
Assembly
U-tube
Vent Adapter
(Not Shown)
a = 14" (36 cm)
Reflector Width (Not Shown)
b = 2" (5 cm)
End Cap to Burner
c = 2" (5 cm)
End Cap to Hanger
d = 7' 6" (2.3 m)
Distance First Hanger
e = 10' (3.0 m)
Distance Between Hangers
f = 5' (1.5 m)
Distance Between Last Full Tube
Hanger and Half Tube Hanger
g = 12.5" (32 cm) Burner Length
h = 11" (28 cm) Burner Height
* Requires the last reflector
before the u-tube to be cut in
half for use on both sides.
** Requires the last tube before
the u-tube to be cut in half for
use on both sides.
b
c
g
e
h
'
20
(6.1 m) Tube Length*
b
c
g
d
h
'
30
(9.1 m) Tube Length**
b
c
g
d
h
'
40
(12.2 m) Tube Length
b
c
g
d
h
'
50
(15.2 m) Tube Length* **
SECTION 7: O
H
A
PTIONAL
EATER
f
e
e
f
29 of 63