1.6
Reading Model Numbers
Model
Number
Family
of vats
3FQG120TNG
1 = FilterQuick
2 = E-electric or G-gas
3 = 80, 100, 120 lbs
4 = T for Tube, U for open
5 = Gas-NG (Natural), PG(Propane), BG(Butane),
LG(LPMix) or Kilowatts -14, 17, 22kW;
1.7
Functional Description
FQG80T/100T/120T Series gas fryers contain a welded stainless steel frypot heated by gas flames diffused evenly
through tubes built into the frypot.
Flames originate from orifices in a burner manifold positioned beneath cast-steel burners.
positioned in the tube openings at the front of the frypot. The diameter of the orifices differs for natural and LP gas
as indicated in the accompanying table.
INPUT
MODEL
(BTU)
125,000
FQG80T
115,000
CE/UKCA
FQG100T
105,000
FQG120T
119,000
An electromechanical gas valve regulates gas flow to the manifold.
equipped with a 24V ignition system.
1.8
Ignition System
The ignition module located inside the control box performs three important functions: It provides an ignition spark,
supplies voltage to the gas valve, and proofs the pilot flame.
The module contains a 90-second time delay circuit and a coil that activates the gas valve. The ignitor assembly
consists of a spark plug, a pilot, and a flame sensor element.
Vat
2
Fuel
1
3
capacity
Vat type
GAS INFORMATION (Altitudes of 2000 feet or less)
GAS
ORIFICE
TYPE
MM
NAT
2.26
LP
1.40
NAT
2.20
LP
1.40
NAT
2.04
LP
1.30
5
Gas or kW
4
ORIFICE
QTY
PART NO.
8102938
5
8102939
5
8103132
5
8102939
5
8103055
5
8103059
5
FQG80T/100T/120T series gas fryers are
1-6
The burners are
EQUIPMENT
PRESSURE
INCH
MBAR
W.C.
10
4
24.8
10
10
4
23.9
9.60
10
4
27.5
10.20