RS-232 Interface
Parity (RS-232)
Parity is an error detection routine in which one data bit in each character is set to 1 or 0
so that the total number of 1 bits in the data field is even or odd. It only needs to be
changed if necessary to match the host setting.
None (Default)
Stop Bits (RS-232)
Stop Bits are added to indicate the end of each character. This setting should only be
changed if necessary to match the host setting.
2 Stop Bits (Default)
Data Bits (RS-232)
Data Bits are the total number of bits in each character. This setting only needs to be
changed if necessary to match the host setting.
8 Data Bits (Default)
Save Settings
4-6
Odd
1 Stop Bit
7 Data Bits
SIMATIC MV340 User's Manual
Even