Kohler 14EKOZD Operation page 87

Marine generator sets
Hide thumbs Also See for 14EKOZD:
Table of Contents

Advertisement

18
15
1.
Silencer vertical lift 1.2 m (4 ft.) max.
2.
Exhaust mixer elbow distance above waterline. If less
than 23 cm (9 in.), a siphon break is required.
3.
Siphon break distance above waterline 30.5 cm
(1 ft.) min.
4.
Siphon break
5.
Exhaust mixer elbow
6.
Heat exchanger (locations vary by model)
7.
Coolant recovery tank
8.
Seawater strainer
9.
Seacock
Siphon Break (Plastic "U" Type) Installation
Figure 43
Note:
Consult the installation manual for complete explanation of dimensions and other installation considerations.
TP-7044
6/23
17
Waterline
16
4
3
2
1
12
13
14
10. Intake strainer
11. Engine-driven seawater pump
12. Exhaust hose pitch 1.3 cm per 30.5 cm (0.5 in. per ft.) min.
13. Water lock (optional)
14. Silencer distance from exhaust mixer elbow 3 m (10 ft.) max.
15. Maximum distance between silencer and exhaust outlet of 1.5 m
(5 ft.)
16. Silencer (customer supplied)
17. Exhaust hose pitch 1.3 cm per 30.5 cm (0.5 in. per ft.) min.
18. Exhaust outlet distance above the waterline 10 cm (4 in.) min.
5
6
11
10
7
8
9
TP-5586-3
87

Hide quick links:

Advertisement

Table of Contents
loading