Engine Start Delay displays the time delay before the generator set starts while the master switch is in AUTO or RUN
positions.
Starting Aid Delay displays the engine starting aid activation time.
Crank On Delay displays the time allocated for generator set crank on in seconds.
Crank Pause Delay displays the time allocated for generator set crank pause in seconds.
Engine Warmed Up displays the temperature when the engine is warmed up enough to be loaded.
Engine Cooled Down displays the temperature below which the engine cooldown can be overridden.
Cooldown Delay displays the time delay for engine cooldown while the master switch is in the AUTO or RUN positions
and not in the idle mode.
Cooldown Override allows the user to select the Cooldown Temperature Override Mode. If set to ON, the engine will
stop immediately if the coolant temperature is below the engine cooled threshold, but will run for the duration of the
cooldown cycle otherwise. If set to OFF, the engine will always complete the cooldown cycle.
Fuel Type displays the programmer entered fuel type as NG (Natural Gas), LP (Liquefied Petroleum), Gasoline, Diesel,
or Unknown.
Crank Cycles Limit displays the programmer entered crank cycle.
Enable NFPA Defaults: Allows the user to Enable or Disable the NFPA defaults.
Enable Emergency Battlemode: Allows the user to turn On/Off the emergency battlemode feature.
Note:
Conditional for certain units.
Protection Configuration
Note:
The time delays are user adjustable using SiteTech™. Have setup and adjustments of the Decision-Maker
performed only by an authorized Kohler distributor/dealer. The setup and adjustments are password protected.
Overvoltage displays the percentage of the system voltage that the generator voltage must exceed for an overvoltage
condition to be indicated.
Overvoltage Delay displays the time that the generator voltage must be in an overvoltage condition before a fault is
indicated.
Undervoltage displays the percentage of the system voltage that the generator voltage must drop below for an
undervoltage condition to be indicated.
Undervoltage Delay displays the time that the generator voltage must be in an undervoltage condition before a fault
is indicated.
Overfrequency displays the percentage of the system frequency that the generator frequency must exceed for an
overfrequency condition to be indicated.
Underfrequency displays the percentage of the system frequency that the generator frequency must drop below for
an under frequency condition to be indicated.
Overspeed displays the engine speed that the engine must exceed for an overspeed condition to be indicated.
Low Battery Voltage displays the system battery voltage that the battery voltage must drop below for a low battery
voltage condition to be indicated.
High Battery Voltage displays the system battery voltage that the battery voltage must exceed for a high battery
voltage condition to be indicated.
28
®
3500 controller
TP-7044