Kohler 14EKOZD Operation page 82

Marine generator sets
Hide thumbs Also See for 14EKOZD:
Table of Contents

Advertisement

Bleed Procedure (14-24EKOZD & 12-20.5EFKOZD Models)
1.
Remove the coolant fill cap. See the Typical (14-24EKOZD and 12-20.5EFKOZD Models) figure in the Service Views
section for location.
Note:
For 21/24EKOZD 60 Hz models, proceed to Step 2. For all other models, proceed to Step 6.
2.
Slowly fill the coolant system until observing coolant at the first bleed point (lowest port) with the plug removed.
See Figure 38.
3.
After seeing coolant, use a funnel to fill the coolant at this port until full. Cap this port.
4.
Slowly fill the coolant system until observing coolant at the second bleed point with the plug removed. See Figure 38.
5.
After seeing coolant, use a funnel to fill the coolant at this port until full. Cap this port.
6.
Slowly fill the coolant system until observing coolant at the third bleed point (highest port) with the plug removed.
See Figure 38.
7.
After seeing coolant, use a funnel to fill the coolant at this port until full. Cap this port.
8.
Fill the coolant system at the filler neck to just below the overflow tube opening.
9.
Lightly squeeze the end coolant hose to ensure that any loose air pockets are bled from the system.
10.
Replace the coolant fill cap.
st
1.
1
bleed point (only available on 21/24EKOZD 60 Hz models)
nd
2.
2
bleed point (only available on 21/24EKOZD 60 Hz models)
rd
3.
3
bleed point
Figure 38
Bleed Point Locations
82
Top View Engine
2
3
1
TP-7044
6/23