Compressor data
Ambient air temperature
Amperage
High-side pressure (psi)
Low-side pressure (psi)
Condenser water
temperature
Amperage
High-side pressure (psi)
Low-side pressure (psi)
Locked rotor amps
Condenser water usage:
Gearmotor data
Gearmotor current
Locked rotor amps
32
60 F/15.6 C
70 F/21.1 C
220 V
230 V
220 V
2 .65
2 .25
2 .77
219
199
256
28
29
30
60 F/15.6 C
70 F/21.1 C
220 V
230 V
220 V
2 .8
2 .4
2 .9
290
290
291
31
32
31
220 V: 19 .6A
@70 F/70F: 0 .26 gal/min
220 V/60 Hz
1 .0A (nominal)
6 .8A
Air-cooled
80 F/26.7 C
230 V
220 V
230 V
2 .36
2 .89
2 .46
233
293
266
31
33
33
Water-cooled
80 F/26.7 C
230 V
220 V
230 V
2 .5
2 .9
2 .5
291
292
292
32
32
33
230 V: 18 .2A
@90 F/70F: 0 .56 gal/min
230 V/50 Hz
1 .3A (nominal)
6 .8A
90 F/32.2 C
100 F/37.8 C
220 V
230 V
220 V
3 .01
2 .57
3 .13
330
306
367
35
36
38
90 F/32.2 C
100 F/37.8 C
220 V
230 V
220 V
2 .9
2 .5
3 .0
292
293
293
32
34
33
C/E25CI425A/W, C/E50CI425A/W
230 V
2 .68
346
38
230 V
2 .6
294
34