9. Loosen phillips-head screw on nozzle connected to evaporator . Remove nozzle from evaporator side only,
leave other side of nozzle connected to transport tube .
10. Place one Sani-Sponge in remaining SafeCLEAN Plus solution .
11. Insert the sponge soaked in sanitizing solution into nozzle then insert a dry sponge into the nozzle .
12. Replace nozzle onto evaporator and tighten screw . Ensure drain is connected to reservoir and vent tubes
are connected to evaporator drain pan .
13. Turn ON bin signal switch . Wait for ice to push sponges through transport tube .
14. Collect sponges from ice storage bin .
15. Replace hopper lid (access cover for CT models), machine top, turn ON dispenser power and install front
cover .
16. After 10 minutes, dispense all ice and discard .