517766B
15.2

Size Setting - IW

To set the size, turn the power on at the power
point and off at the console. Press and hold the
FABRIC CARE button, then press the POWER
button. This will present a set of options in the
LCD screen.
The LCD screen has within it a number of
options.
Push the Adjust button to highlight
650mm (L). Pushing the POWER button will
lock the "size" into the module's memory.

16. DIAGNOSTIC MODE

16.1

GW (Ecosmart)

Turn the power on at the power point but off at the machine. Press and hold the WASH
TEMP DOWN button and then the POWER button until the machine gives 2 short beeps
and lights up.
Release buttons when the beeps indicate diagnostic mode has been
entered.
Note: The power button is relocated to the left of the panel but central to the console, not
on the right hand side as with all previous GW SmartDrive machines.