6
|
Application guidelines
6.4.4 DHW pump for instant hot water
6.4.5 DHW pump for disinfection
Installer reference guide
54
Setup
a
a Cold water IN
b Hot water OUT (shower (field supply))
c DHW pump (field supply)
d Recirculation connection
▪
By connecting a DHW pump, instant hot water can be available at the tap.
▪
The DHW pump and the installation are field supply and the responsibility of the
installer. For the electrical wiring, see
4
pump" [
142].
▪
For more information about connecting the recirculation connection, see
"8.6.4 To connect the recirculation
Configuration
▪
For more information, see "11 Configuration" [
▪
You can program a schedule to control the DHW pump via the user interface. For
more information, see the user reference guide.
Setup
a
a Cold water IN
b Hot water OUT (shower (field supply))
c DHW pump (field supply)
d Heater element (field supply)
e Non‑return valve (field supply)
▪
The DHW pump is field-supplied and its installation is the responsibility of the
installer. For the electrical wiring, see
4
pump" [
142].
c
d
"9.3.5 To connect the domestic hot water
4
piping" [
119].
4
b
c
d
e
"9.3.5 To connect the domestic hot water
b
155].
ERRA08~12E + ELVH/X12S18+23E
Daikin Altherma 3 R MT F
4P708474-1 – 2023.05