To connect the FortiGate-7030E chassis to ground
Chassis
Ground
Connector
Data Center
1. Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal surface on the chassis or frame.
2. Make sure that the chassis and ground wire are not energized.
3. Connect the green ground wire from the local ground to the ground connector on the FortiGate-7030E chassis.
4. Secure the ground wire to the chassis.
5. Optionally label the wire GND.

Turning on FortiGate-7030E chassis power

Connect AC power to PWR1, PWR2 and PWR4. Once the FortiGate-7030E chassis is connected to power the chassis
powers up. If the chassis is operating correctly, the LEDs on the PSUs and fans should be lit. As well, the LEDs on the
FortiGate-7030E SMM should be lit.
When the chassis first starts up you should also hear the cooling fans operating.
In addition, if any modules have been installed in the chassis they should power on and their front panel LEDs should
indicate that they are starting up and operating normally.