Compressor Backup Operation Setting - Toshiba MMY-MAP0806FT8P-TR Service Manual

Table of Contents

Advertisement

9-2. Compressor Backup Operation Setting

<Outline>
If a fault occurs to one of the compressors installed in outdoor unit, follow the procedure described below to
back up the faulty compressor by using the remaining, normal compressor.
<Work Procedure>
(1) Turn off the power supply to all the outdoor units connected to the system.
(2) Set the DIP switches of SW06, provided on the interface P.C. board of the outdoor unit with the faulty
compressor, as shown in the table below.
F
a
c
When compressor No.1 (front left) is faulty
When compressor No.2 (front right) is faulty
Two-compressor model
o t
y r
d
e
a f
u
t l
s
e
t t
n i
g
SW06
SW07
SW09
1 2 3 4
1 2 3 4
1 2 3 4
SW11
SW12
SW13
1 2 3 4
1 2 3 4
1 2 3 4
SW16
SW17
1 2 3 4
1 2 3 4
SW06
Bit 1
Bit 2
Bit 3
O
F
F
O
F
F
O
F
ON
OFF
OFF
OFF
ON
OFF
− 244 −
SW10
1 2 3 4
SW14
1 2 3 4
Bit 4
F
O
F
F
OFF
OFF