Error
Description
60-69
Internal
communication events
A0-A4
Picker Servo Errors
A5
Source Element Empty
A6
Source Magazine
Missing
Suggested Actions
• Power cycle.
• If the previous steps fails, contact Quantum Customer
Support and/or replace the DCA.
• Run the Health test.
• If repeated events appear in the Hard log, power cycle
the SuperLoader. Repeat tests after power cycle.
• If the previous steps fails, contact Quantum Customer
Support and/or replace the chassis/picker assembly.
• Verify that the expected source really does have a
cartridge.
• Run the Health test.
• If the source is a magazine, replace the cartridge in that
slot with a different cartridge and try again. If error
continues, replace the magazine.
• If source is the tape drive, verify the tape drive has a
cartridge and it was ejected.
• Power cycle the SuperLoader.
• If the error continues, contact Quantum Customer
Support and/or replace the chassis/picker assembly.
• Verify that the magazine is installed correctly into the
SuperLoader.
• Remove and insert the magazine again.
• Try a second magazine if possible.
• Power cycle the SuperLoader.
• If the error continues, contact Quantum Customer
Support and/or replace the chassis/picker assembly.