8.7 Connecting the gas piping

8.7.1 To connect the gas pipe

8.7.2 To perform an air purge on the gas supply

Installer reference guide
108
In case of EHYHBX
a Drain pan kit
1 Connect a gas valve to the 15  mm gas connection of the gas boiler and
connect it to the field pipe according to local regulations.
2 Install a gas mesh filter in the gas connection if the gas may be contaminated.
3 Connect the gas boiler to the gas supply.
4 Check all parts for gas leaks on a pressure of maximum 50  mbar
(500 mm H
O). There may be no stress on the gas supply connection.
2
1 Turn once the screw counterclockwise.
a
0.0 mm
EVLQ05+08CA + EHYHBH05A + EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09