RUGGEDCOM RSG2100
Installation Guide
Test
IEC 61000-4-29
IEC 61000-4-11
IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
IEC 60255-5
a
Siemens-specified severity levels
IEEE 1613 EMC Immunity Type Tests
NOTE
The RUGGEDCOM RSG2100 meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports.
ESD
Radiated RFI
Fast Transient
EMC and Environmental Type Tests
Description
Voltage Dips and
Interrupts (DC
Power Ports)
Voltage Dips and
Interrupts (A. C.
Power Ports)
Damped Oscillatory
Mains Frequency Voltage
Ripple on DC
Power Supply
Dielectric Strength
HV Impulse
Description
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
1000 A/m for 1 s
DC Power Ports
100% for 0.05 s
AC Power Ports
30% for 1 period
60% for 50 periods
AC Power Ports
100% for 5 periods
100% for 50 periods
Signal Ports
2.5 kV Common,
1 kV Differential
DC Power Ports
Mode @1 MHz
AC Power Ports
Signal Ports
30 V Continuous,
DC Power Ports
DC Power Ports
Signal Ports
2 kV (Fail-Safe
DC Power Ports
AC Power Ports
Signal Ports
5 kV (Fail-Safe
DC Power Ports
AC Power Ports
Test Levels
Severity Levels
30% for 0.1 s
60% for 0.1 s
300 V for 1s
10%
Relay Output)
2 kV
2 kV
Relay Output)
5 kV
Test Levels
+/- 2 kV, +/-4 kV, +/-8 kV
+/-4 kV, +/-8 kV, +/-15 kV
35 V/m
+/- 4 kV @ 2.5 kHz
+/- 4 kV
+/- 4 kV
Chapter 6
Certification
5
3
4
3
43