Configuring Dynamic Ip Address Assignment - Siemens SIMATIC NET SCALANCE M-800 Getting Started

Industrial remote communication remote networks
Table of Contents

Advertisement

2.1

Configuring dynamic IP address assignment

The devices whose MAC address or whose client ID was not specified specifically, are
assigned a random IP address from a specified address range.
Procedure
1. Click on "System > DHCP" in the navigation area and on the "DHCP server" tab in the
content area.
2. Click "Create". A new row with a unique number (pool ID) is created in the table.
3. Enter the network address range in "Subnet". Since the device being used is operating
both as a gateway and a DNS relay, the IP address 192.168.100.1 must be in the
network address range. In this example the network address: 192.168.100.0/24 (=
192.168.100.0 / 255.255.255.0) is used.
4. In "Lower IP Address", enter the IP address 192.168.100.20 that specifies the start of the
dynamic address band and that is located within the network address range.
5. In "Upper IP Address", enter the IP address 192.168.100.120 that specifies the end of the
dynamic address band and that is located within the network address range.
6. Click on "Set Values".
7. To activate the DHCP server, select "DHCP Server".
8. Enable "Probe address with ICMP echo before offer" to enable the ping function. With this
ping, the DHCP server checks whether or not the IP address has already been assigned.
SCALANCE M-800
Getting Started, 07/2020, C79000-G8976-C337-09
SCALANCE M-800 as DHCP server
2.1 Configuring dynamic IP address assignment
49