1.11
Additional steps in configuration with the SCALANCE M826 in
routing mode
1.11.1

Creating IP subnet

In routing mode, the interfaces are handled differently.
● Ethernet interface: Connection of the internal IP subnet (vlan 1)
● SHDSL interface: Connection of the external IP subnet (vlan 2)
The Ethernet interface or the internal IP subnet has already been configured with the SINEC
PNI. For this configuration example, only the IP subnet for the SHDSL interface or for the
external IP subnet needs to be configured. The same steps need to be taken on all devices.
Procedure
1. Click on "Layer 3 > Subnets" in the navigation area and in the "Configuration" tab in the
content area.
2. For "Interface (Name)" select the entry "vlan2".
3. For "Interface Name" you can enter a name.
4. Enter the value assigned to the M826 from the "Settings used (Page 12)" table.
5. Click on "Set Values".
SCALANCE M-800
Getting Started, 07/2020, C79000-G8976-C337-09

1.11 Additional steps in configuration with the SCALANCE M826 in routing mode

Connecting SCALANCE M-800 to WAN
39