Rs232 Pc Interface Connection - Omega Engineering OS100E Series User Manual

Mini-infrared transmitters
Table of Contents

Advertisement

3.7
RS-232
OS101E/OS102E RS232 Command Reference:
Note: All commands sent to the OS100E series must be terminated by
a carriage return or carriage return and linefeed, and is shown in this
document as "CR" and "LF". Any parameters shown in square brackets
"[ ]" are optional. Parameters are separated from commands and from
each other by a space " ". Spaces within commands are shown in this
document as "SP". All commands are case insensitive, meaning any
combination of upper/lower case characters are accepted.
In order to communicate with the OS101E/OS102E, the terminal (or
PC running a terminal program such as HyperTerminal) must have the
following serial communication settings:
Baud:
Data Bits:
Parity:
Stop Bits:
Handshaking: None
C Command:
Description: - Transmit Target temperature in Deg C (one time).
Syntax:
Parts:
Remarks:
Example:
Assuming target temperature is 125 °C, the following is shown on the
PC (terminal) screen after typing "C" and "Enter":
C
125
GND
Tx
Rx
1
5
PC SERIAL PORT
Figure 3-5. RS232 PC Interface Connection
19200
8
None
1
C CR [LF]
None. There are no parameters for this command.
None.
OS100E Series - Operation
1
2
3
4
5
Rx
6
Tx
7
8
9
3
3-5