User’s Guide CAUTION! – This product is not intended for medical use or use on humans Shop online at omega.com OS101E e-mail: info@omega.com For latest product manuals: www.omegamanual.info OS102E OS100E SERIES Mini-Infrared Transmitters...
Table of OS100E Series Infrared Transmitter Contents Table of Contents Section ..............Page Safety Warnings and IEC Symbols ........ iii Caution and Safety Information ........iii Section 1 Introduction ..............1-1 Section 2 Installation ..............1-1 2.1 Unpacking and Inspection ........1-1 2.2 Electrical Connection ..........
Page 4
Table of OS100E Series Infrared Transmitter Figures Table of Figures Figure Description Page Power Supply & Analog Output Connections ..2-1 Alarm Output Connection ........... 2-1 Main PC Board ............... 3-2 Sensor Housing .............. 3-2 Optical Field of View ............ 3-4 Setting the Temperature Engineering Unit ....
OS100E Series Safety Warnings and IEC Symbols This device is marked with international safety and hazard symbols in accordance with IEC 1010. It is important to read and follow all precautions and instructions in this manual before operating or commissioning this device as it contains important information relating to safety and EMC.
OS100E Series - Introduction Section 1 - Introduction The low cost OS101E mini-infrared transmitter provides non-contact temperature measurement for industrial applications. The unit measures a temperature range of -18 to 538°C (0-1000°F) and provides a linear analog output of either 4-20 mA, 0-5 Vdc, K type TC, 1 mV/°C, or 1 mV/°F.
OS100E Series - Installation The following describes the ordering information: OS102E or OS101E - MA - **, where MA - 4/20 mA output HT- High V1 - 0 to 5 Vdc output temperature K - Thermocouple output, K type sensor head...
OS100E Series - Operation 7 8 9 DS2 DS3 DS4 DISPLAY BOARD INSTALLED ON MODEL OS102E ONLY Figure 3-1. Main PC Board Ambient Temperature The Sensing head can operate in an ambient temperature of 0 to 70°C (32 to 158°F). The Sensing head in the high temperature model (-HT) can operate in an ambient temperature of 0 to 85°C (32 to 185°F) without any...
OS100E Series - Operation Atmospheric Quality Environments with smoke, dust, and fumes dirty up the optical lens, and cause erroneous temperature readings. To keep the surface of the optical lens clean, the air purge collar accessory is recommended, OS100-AP, See Fig.
OS100E Series - Operation COVER 7 8 9 NOTE: OPEN THE COVER OF THE MAIN HOUSING & SET THE JUMPER SW1 TO F OR C. Figure 3-4. Setting the Temperature Engineering Unit Alarm Setting The unit provides 0-100% alarm set point adjustment. Here is an example of an alarm setting.
Figure 3-5. RS232 PC Interface Connection OS101E/OS102E RS232 Command Reference: Note: All commands sent to the OS100E series must be terminated by a carriage return or carriage return and linefeed, and is shown in this document as “CR” and “LF”. Any parameters shown in square brackets “[ ]”...
Page 14
OS100E Series - Operation F Command: Description: - Transmit Target temperature in Deg F (one time). Syntax: F CR [LF] None. There are no parameters for this command. Parts: None. Remarks: Example: Assuming target temperature is 257 °F, the following is shown on the PC (terminal) screen after typing “F”...
Page 15
OS100E Series - Operation VERSION Command: Description: - Transmit model number, firmware version, and output mode. Syntax: VERSION CR [LF] None. There are no parameters for this command. Parts: Remarks: Units with a display attached will transmit “OS102E” as the model number.
Page 16
OS100E Series - Operation Example 1: The following is shown on the PC (terminal) screen after typing “AMODE” and “Enter”. The activation mode is not changed, but it is reported. AMODE ALARM MODE SET FOR RISING TEMP. > Example 2: The following is shown on the PC (terminal) screen after typing “AMODE 0”...
Page 17
OS100E Series - Operation CABLE Command: Description: - Set/Transmit cable length compensation. Syntax: CABLE[ S P LENGTH] C R [ L F ] Parts: LENGTH (OPTIONAL) Specifies the total length (in feet) of cable attached between the sensor head and the transmitter box. The valid range for this parameter is 6 to 56.
Section 4 – Software Software Overview The OS100-Soft application enables you to communicate with your OS100E Series transmitter on a PC using serial communication. The application has the following capabilities: • Real-time display of temperature reading. • Data acquisition and plotting of real-time data.
OS100E Series - Software • Windows XP or newer operating system. • At least 512 MB Ram. • 280 MB available hard drive space. 4.3.2 Software Installation Insert the OS100-Soft CD into your computer’s CD-Rom drive. The installation program should start up automatically. If it does not start automatically locate and run the Setup.exe file on the CD.
OS100E Series - Software This is followed by the Confirm Installation Screen. If satisfied with click “Next>” button to begin installation, otherwise use “<Back” button to navigate to and change settings as needed. Figure 4-2. Confirm Installation Screen A license agreement for the OS100-Soft is next displayed, plead read and select “I agree”...
OS100E Series - Software Figure 4-3. OS100-Soft License Agreement The installation process then begins and the Installation Complete screen is displayed when done. Click “Close” button to finish. 4-4...
OS100E Series - Software Congratulations! You have successfully installed the OS100-Soft program and you can now use it to communicate with your OS100E series unit(s). Using Software To run the application click on the desktop shortcut (if present) or access the program from the Start Menu, Start\Programs\OS100-SOFT\OS100- Soft.exe (or select path installed if different).
OS100E Series - Laser Sight Accessory Section 5 - Laser Sight Accessory Warning and Cautions CAUTION: You may receive harmful laser radiation exposure if you do not adhere to the warnings listed below: • Use of controls or adjustments or performance of procedures other than those specified here may result in hazardous radiation exposure.
OS100E Series - Laser Sight Accessory LASER WARNING LABEL SENSOR HEAD DC POWER JACK LED LASER LASER BEAM POWER (.75) INDICATOR 50.8 (2.0) ON/OFF SWITCH POWER CABLE Dimensions mm (in.) BATTERY PACK POWER SUPPLY Figure 5-1. Laser Sighting Accessory, OS100-LS ®...
OS100E Series - Specifications Section 6 - Specifications General -18 to 538°C (0 to 1000°F) Temperature Range: Accuracy @ 22°C (72°F) ± 2% of Rdg. or 2.2°C (4°F) whichever is greater ambient temperature & emissivity of 0.95 or greater: 6:1 (Distance/Spot Size) Optical Field of View: ±...
OS100E Series - Specifications General Con’t. Dimensions 25.4 OD. x 63.5 mm L (1" OD. x 2.5" L) Sensor Head: Main Housing: 65.5 W x 30.5 H x 115.3 mm L (2.58 W x 1.2 H x 4.54" L) 272 g (0.6 lb)
Page 31
OS100E Series - Emissivity Table Section 7 - Emissivity Table Material Emissivity (ε) Aluminum – pure highly polished plate ..... . .
Page 32
OS100E Series - Emissivity Table Material Emissivity (ε) Asbestos Board ..........0.96 Asphalt, tar, pitch .
Page 35
WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 25 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal two (2) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
Page 36
Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE M U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies M U Wire: Thermocouple, RTD & Thermistor M U Calibrators & Ice Point References M U Recorders, Controllers &...