5.3. Communication Configuration

5.3.1. COM Port For MSCS
• Com Port connects or disconnects the communication between PC and MLCD.
• Connect MLCD to PC Com Port via RS-232C cable.
• Go to MSCS Menu  Communication and set Com Port. Click 'Connect' using mouse or press 'Ctrl+C' using keyboard.
• In order to disconnect communication, click 'Disconnect' using mouse or press 'Ctrl+D' using keyboard.
• When you use USB-to-RS-232C converters, you need to set Com Port again, because MSCS uses
one of Com Port no. 1 to 30.
※Available Com Port on the PC is automatically recognized and displayed.
• Com Port Configuration
Baud Rate
115200bps(Fixed)
Data Bit
8Bits
Parity
None
Stop Bit
1Bit
Flow Control
None
- 34 -
5.3.2. LAN Port for MSCS
1. Execute the MSCS.
2. Select "MenuCommunication  Setup" or"Ctrl+U" to start setup.
3. Select "Socket" radio button.
4. Type in IP Address of MLCD.
5. Click "Ping Test" to check status of communication.
6. Close the Commnication setup window
• Menu Description
• Serial : Set the serial communication as a default communication.
• Com Port : Set the port of a PC to communicate with MLCD.
• Baud Rate : Fixed at 115200bps.
※ Caution: Users cannot change the Baud rate.
• Socket : Set the Ethernet LAN communication.
• Edit Box : Set the IP address.
• Port Number : Fixed as 9761.
※ Caution: Users cannot change the port number.
• Ping Test: Test the IP address.
• Connect : Connect the communication.
Communication Setup
- 35 -