Orion OPM-4240 User Manual

Orion OPM-4240 User Manual

Infinitely expandable mpdp

Advertisement

Quick Links

A revolutionary MPDP
Infinitely Expandable MPDP
ORION PDP CO.,LTD.
www.oriondisplay.net
Address: 257-6, Gongdan-dong, Gumi-si, Gyeongsangbuk-do, Korea
Tel : +82-2-6678-8533,
Fax: +82-2-6678-8599
A revolutionary MPDP
Infinitely Expandable MPDP
User's Manual
OPM-4240 / OPM-4240R
Thank you for purchasing our MPDP.
Please read through this user's manual for safety before installing this product.
This product is manufactured for Multi Plasma display model only.

Advertisement

Table of Contents
loading

Summary of Contents for Orion OPM-4240

  • Page 1 A revolutionary MPDP Infinitely Expandable MPDP User’s Manual A revolutionary MPDP Infinitely Expandable MPDP OPM-4240 / OPM-4240R ORION PDP CO.,LTD. www.oriondisplay.net Address: 257-6, Gongdan-dong, Gumi-si, Gyeongsangbuk-do, Korea Tel : +82-2-6678-8533, Fax: +82-2-6678-8599 Thank you for purchasing our MPDP. Please read through this user's manual for safety before installing this product.
  • Page 2: Important Safety Instructions

    Infinitely Expandable Features of MPDP Notice to users ▶ Enjoy a wide flat screen with high brightness and high quality. Class A digital device ▶Easy to install and move due to its thin design It is a device designed for business purpose with a safety certificate for electromagnetic interference, which ▶...
  • Page 3: Table Of Contents

    ......................10 Burn-In-Compensation Control Method ...............43 BIC Intervals and effect ...................43 3.GuidanceforUsers ....................14 How to Control BIC ....................44 5.15. Orion PDP Home Page logon and Version information ........49 4.HowtoConnectCables ..................16 6.MSCSProtocol .......................50 4.1. Connection of one set MPDP .................16 ※Attachment : ASCII to HEX Conversion Table ..........64 PC &...
  • Page 4: P LeaseKeepFollowingInstructionFor

    OPM-4240 / OPM-4240R Infinitely Expandable ※ Please keep following ※Handle with Caution. instruction for panel protection - Shock/Impact on the set's sides will result in internal circuit damages. without exception. - The edge/bottom of the panel are fragile. Warning Warning...
  • Page 5 OPM-4240 / OPM-4240R Infinitely Expandable Open Structure How to carry MPDP Pleaseseepage8forunpackandhandleassembly. UnlikeconsumerPDPproduct,thepanelofMPDPisexposedwithout ItalwaysneedstwopersonstocarryorinstallMPDP. anyprotectivechassis. WhenyoucarryMPDPwithupstraightmanner,pleaseholdhandlesontheback Itneedsextracautiontocarryorinstalltopreventanyimpact. andbottompartofthepaneltogether. Pleasebecarefulnottotouchthebottompartofthepanelwhenyouputdownthe MASTER FRAME panel. PANEL Please do not touch the panel with your hand. WhenyoucarryMPDPwithflatbedmanner,pleaseholdhandlesonthebackand • OPM-4240 • OPM-4240R lowerpartoftheback. Pleasebecarefulnottotouchthebottompartofthepanelwhenyouputdownthe panel.
  • Page 6: SafetyPrecautions

    OPM-4240 / OPM-4240R Infinitely Expandable 1. Safety Precautions • If it operates abnormally, stop using it • Do not place any liquid-containing • Do not pull out or hang down the • Do not lean against the product or keep •...
  • Page 7: HowToInstall

    OPM-4240 / OPM-4240R Infinitely Expandable 2. How to install Install this set only at a location where adequate ventilation is available. How to assemble handles How to move MPDP 1.2peopleholdeachhandleonproduct'sbackside. 1.ProductispackedinaboxasshowninFigure1. Panel protection 2.PleasecarefullyremovethePackingBagwithaknifeorapairofscissors. ※ Please check front and rear side before you cut the bag to prevent any damages on panel or set.
  • Page 8 OPM-4240 / OPM-4240R Infinitely Expandable Main FraME Stand Unit (Option) Main FraME Wall Mounting Unit (Option) Please do not install our product at following locations to protect the product and Please check the stability of wall. prevent possible malfunction. If the wall is not strong enough, reinforce the wall before installation.
  • Page 9: GuidanceForUsers

    OPM-4240 / OPM-4240R Infinitely Expandable 3. guidance for Users input/Output Terminals Set iD Switch Setting Example of ID Switch setting - You can set ID with 3 rotary switches as shown in the following figure. [PDP ID 01] 100 digit...
  • Page 10: Connection Of One Set Mpdp

    OPM-4240 / OPM-4240R Infinitely Expandable 4. How to Connect Cables 4.1. Connection of one set MPDP PC & DVi Connection MPDP and PC should be connected; a Com Port in a PC and RS-232C IN port in a MPDP is connected with supplied RS-232C cable.
  • Page 11: Vcr Connection

    OPM-4240 / OPM-4240R Infinitely Expandable VCr Connection [PDP ID 1] RS-232C (Maximum 15m) ID switch must be set as ID 1 for one set use. VIDEO RS-232C PC(MSCS) to control MPDP S-VIDEO COMPONENT Video connection (Maximum 5m) S-Video connection (Maximum 5m)
  • Page 12: Dvd Player & Dtv Set Top Box Connection

    OPM-4240 / OPM-4240R Infinitely Expandable DVD Player & DTV Set top box connection In case input source is DVD(480p, 576p, 480i, 576i), select DVD in MSCS main screen. In case input source is DTV(720p, 1080i, 1080p), select DTV in MSCS main screen.
  • Page 13: Connection Of Multi-Screen Mpdp

    OPM-4240 / OPM-4240R Infinitely Expandable 4.2. Connection of Multi-screen MPDP Recommended maximum set connection for Multi setting is shown in table below. If you need to connect more than described in the table, you have to use distributors. Image quality can be affected by cable or signal quality.
  • Page 14: Connection Of Rs-232C Cable

    OPM-4240 / OPM-4240R Infinitely Expandable 4.3. Connection of rS-232C Cable 4.4. Connection of 3 x 3 MPDP Maximum use of RS-232 with Daisy Chain connection is or less. If you need additional connection, use RS-232 distributor. RS-232C DVI-D RS-232C DVI-D...
  • Page 15: Installation

    OPM-4240 / OPM-4240R Infinitely Expandable 5. Setting and operation of MSCS software 4.5. iD setting of X x Y MPDP [PDP ID 01] 5.1. installation Identity number (ID) indicates the location of each MPDP. Insert the Installation CD. When you look at the MPDP screens in front of MPDP.
  • Page 16: Start Mscs

    OPM-4240 / OPM-4240R Infinitely Expandable 5.2. Start MSCS 5.3. Setting 'Com Port' MSCS is an application program needed to control MPDP. Com Port connects or disconnects the communication between PC and MPDP. When you execute MSCS (v 4.2) for your product at the installation screen, it will create a new folder Connect MPDP to PC Com Port via RS-232C cable.
  • Page 17: Multi-Screen Configuration

    OPM-4240 / OPM-4240R Infinitely Expandable 5.6. MSCS instruction 5.5. Multi-screen configuration Check "ALL PDP" to send data to all connected MPDP regardless of ID. Screen Configuration Setting InputthenumbersofXandY X is for the number of row and Y is for column.
  • Page 18: Configuration Of Various Modes

    OPM-4240 / OPM-4240R Infinitely Expandable 5.9. Setting multi screens at a time 5.8. Configuration of various modes You can select multi screens at a time as you want. You can configure various input sources as you want. Selectadesirableinputsourcein"SourceSelect" SelectadesirableinputSourcein"SourceSelect" Select "DVI" in "Source Select".
  • Page 19: Slide Control

    OPM-4240 / OPM-4240R Infinitely Expandable 5.10. Slide Control MPDP configuration that users set is displaying repeatedly. To use Slide Control, go to MSCS Menu → Control → Slide Control or press "Ctrl+S" using Keyboard. Savevariousscreenconfigurationsinthesameway. Makeadesirableconfigurationin"ScreenConfigurations" Click"SlideStart"todisplaysavedscreenconfigurations. -Saved screen configurations are displaying for preset time.
  • Page 20: Screen Control

    OPM-4240 / OPM-4240R Infinitely Expandable 5.11. Screen Control Register values related to display of MPDP can be changed. Click"Stop"buttontoend"SlideControl" Click "Picture Control" of "Control" menu bar or enter "Ctrl+P" in order to run "Picture Control" window. SaveorLoadtheslideconfiguration Click "SAVE" button to save user added Slide configuration as "*.ssd" file.
  • Page 21: Pc Tracking

    OPM-4240 / OPM-4240R Infinitely Expandable 5.12. PC Tracking 5.13. Timer Control Alignment adjustment is available when input source is PC. Users can decide the time of turning on or off MPDP set by timer control. To use this function, click Menu -> Control-> Timer Control or use 'Ctrl +T' keys from the keyboard.
  • Page 22: Bic Control

    OPM-4240 / OPM-4240R Infinitely Expandable 5.14. BiC Control Select one of BIC mode, BYPASS mode, REGENERAION mode and ANTI IMAGE STICKING mode and You can control BIC functions related with burn-in compensation. click “EXE” to control Burn-in compensation function. Please select "Menu → Control → BIC Control" or "Ctrl+B" to start BIC control.
  • Page 23: Bic Status Indicator

    OPM-4240 / OPM-4240R Infinitely Expandable Burn-in-Compensation Control Method Phosphor Update function changes phosphor value. If you cannot have satisfactory compensation result by adjusting Deterioration function, you can change User can select a color (Red, Green or Blue) for compensation from Deterioration Menu in the BIC phosphor value.
  • Page 24: How To Control Bic

    OPM-4240 / OPM-4240R Infinitely Expandable How to Control BiC 1.MSCS 3. MF-Controller 1) MSCS and MPDP must be always connected. 1) If you want to use the other MPDP control program beside MSCS and you cannot integrate BIC control 2) If MSCS command is executed prior to the BIC command, the BIC command will be executed again program into the MPDP control program, you can use MF-Controller.
  • Page 25 OPM-4240 / OPM-4240R Infinitely Expandable MF-Controller configuration method 6. Start with press "GO" button. 7. Configure the number of horizontally installed MPDP units at first. 1. Connect power. Press "LEFT" and "RIGHT" buttons to begin horizontal configuration. (◀ ▶) 2. Connect female D-sub to the Com port in a computer.
  • Page 26: Orion Pdp Home Page Logon And Version Information

    5.15. Orion PDP Home Page logon and Version information VIDEO S-VIDEO NORMAL 8. Press "UP" and "DOWN" buttons to begin vertical configuration.(▲▼) In order to move to Orion PDP's website, go to "Help" of menu bar → "OrionDisplay HomePage". Enter AUTO 가로설정상태 설정상태 나타냄...
  • Page 27: Mscs Protocol

    OPM-4240 / OPM-4240R Infinitely Expandable 6. MSCS Protocol Introduction 2.2. Receive From PDP This document contains the communication protocol between PDP and its control devices such as computer for better Length Data Check Sum use of the product. However, it does not include detailed technical matters. It rather focuses on the brief functional...
  • Page 28 OPM-4240 / OPM-4240R Infinitely Expandable 3.3. Multi-Scale 3.5. Auto-Power Mode Screen expansion command for MPDP The command for set or cancel automatic power on when AC power is connected Command Code Command Code: 0x62(Set), 0x63(Cancel) 0xDD (DVI), 0xDE (PC), 0xDF (DTV), 0xE0 (DVD), 0xE1(S-Video), 0xE2 (Video)
  • Page 29 OPM-4240 / OPM-4240R Infinitely Expandable 3.9. Tracking Mode 3.10. Input Mode Change Automatic or Manual screen alignment or open previous configuration at PC RGB Mode. This can be used for additional input mode change. Command Code: Command Code: 0x44 (DVI), 0x45 (PC), 0x46 (DTV), 0x47 (DVD), 0x48 (S-Video), 0x49 (Video) 0x4A (Auto-tracking), 0x4B (Get Tracking Values), 0x4C (Frequency- tracking), 0x4D (Phase-tracking),...
  • Page 30 OPM-4240 / OPM-4240R Infinitely Expandable 3.14. Elapsed Time 3.17. Default Data Load (Picture Control Data) Command for finding out how long the set was actually used. Return every adjusted value to default values. All the built-in values are applied. Command code: 0x78 Caution: Existing Picture Control Data will be lost with this command.
  • Page 31 OPM-4240 / OPM-4240R Infinitely Expandable Caution 1: Although ID area value is set as "0x00" to apply the same value to all MPDP, White balance may not be adjusted Data due to the deviation between sets. So, individual White Balance adjustment is recommended.
  • Page 32 OPM-4240 / OPM-4240R Infinitely Expandable 3.24. Get Picture Control Data Data: ID(1 byte) + Status(30 byte) Data Length Explanation Command for finding out the value for current Picture Control Data such as User mode, White Balance, Graphic, and Video. 1 byte Range: 1 ~ 225(for Full MPDP: 15 x 15) Command Code: 0x88 Input Source 1 byte 0x0C: PC, 0x0E: DVI, 0x0D: DTV, 0x07: DVD, 0x05: S-Video, 0x02: Video...
  • Page 33 Command Code: 0x7F Protocol Format - Two way communication (Send to PDP, Receive from PDP) The difference between OPM-4240 Protocol and MIS-4230 Protocol - Caution: It will not respond during Stand-by. It should be executed only during operating status. * Send to PDP 4.1.
  • Page 34: Attachment : Ascii To Hex Conversion Table

    OPM-4240 / OPM-4240R Infinitely Expandable 7. Other tips 7.1. Before calling for service ※attachment : aSCii to HEX Conversion Table Before calling for any repair, check the following and then refer to a near A/S center. ▶"Tick" sound from the main body.
  • Page 35: About Plasma Display Panel

    OPM-4240 / OPM-4240R Infinitely Expandable 8. applicable signals 7.2. about Plasma display panel 8.1. DVD / DTV The followings are phenomena caused by characteristics of the plasma display panel. InputSignal Resolution Remarks Since it is not a fault, you may continue to use the product.
  • Page 36 OPM-4240 / OPM-4240R Infinitely Expandable 9. Specifications Model name Model name OPM-4240 OPM-4240R Power supply 100 ~ 240V AC. 50/60Hz Power supply 100 ~ 240V AC. 50/60Hz Power consumption Power consumption Average (Typical) 300W Average (Typical) 300W 360W 360W Plasma display panel...

This manual is also suitable for:

Opm-4240r

Table of Contents