Address: 257-6, Gongdan-dong, Gumi-si, Gyeongsangbuk-do, Korea Tel : +82-2-6678-8533, Fax: +82-2-6678-8599 User’s Manual OPM-4250 | OPM-4250R Thank you for purchasing our MPDP. Please read through this user's manual for safety before installing this product. This product is manufactured for Multi Plasma display model only.
Features of MPDP Infinitely Expandable ▶ Enjoy a wide flat screen with high brightness and high quality. ▶Easy to install and move due to its thin design Notice to users ▶ E njoy your favorite programs with various split-screen features simultaneously presenting Class A digital device several programs.
Infinitely Expandable OPM-4250 | OPM-4250R Contents ※Cautions for consisting MPDP System ...................4 CAUTION ※ Please keep following instruction for panel protection without exception. ....6 1. Safety Precautions ..........................10 RISK OF ELECTRIC SHOCK 2. How to Install DO NOT OPEN .
Infinitely Expandable OPM-4250 | OPM-4250R ※Cautions for consisting MPDP System The number of Daisy chain connection Environmental condition for installation - S inceMPDPpanelisverysensitiveforphysicalimpact,installationrequires - T heimagequalitycanbevarydependonthequalityofsignalandcable considerablecaution. condition. - M inimumclearance(20cm)mustbesecuredforsmoothventilation.(SeeP14~15) INPUT SOURCE Resolution Connection Remark Installationmustavoidairtightornearairtightplaces.Improperventilationcauses 1600x1200x60HZ 6sets HDCPAvailable malfunctionandshortensproductlifetimebyrapidinternaltemperaturerise.If...
Infinitely Expandable OPM-4250 | OPM-4250R ※ Please keep following ※Handle with Caution. instruction for panel protection - Shock/Impact on the set's sides will result in internal circuit damages. without exception. - The edge/bottom of the panel are fragile. Warning Warning...
Page 6
Infinitely Expandable OPM-4250 | OPM-4250R Open Structure How to carry MPDP Please see page 12 for unpack and handle assembly. Unlike consumer PDP product, the panel of MPDP is exposed without It always needs two persons to carry or install MPDP.
Infinitely Expandable OPM-4250 | OPM-4250R Safety Precautions • If it operates abnormally, stop using it • Do not place any liquid-containing • Do not pull out or hang down the • Do not lean against the product or keep •...
Infinitely Expandable OPM-4250 | OPM-4250R How to install Installthissetonlyatalocationwhereadequateventilationisavailable. How to assemble handles How to move MPDP 1. 2 people hold each handle on product's back side. 1. Product is packed in a box as shown in Figure 1. Panelprotection 2.
Page 9
Infinitely Expandable OPM-4250 | OPM-4250R MAin FrAME Stand Unit (Option) MAin FrAME Wall Mounting Unit (Option) Pleasedonotinstallourproductatfollowinglocationstoprotecttheproductand Pleasecheckthe stabilityofwall. preventpossiblemalfunction. Ifthewallisnotstrongenough,reinforcethewallbeforeinstallation. -Placesofvibrationorshock:PDPsetmayfallanddamaged - N extorneartoSprinklersensors:Thesensorsmaydetectheatfromasetandsprinklercanbeactivated. Pleaseconnectallthecablestoproperportsinasetbeforeinstallation. -Aroundhighvoltagepowerlines:Noisefromthepowerlinemayaffectscreenimages -Aroundheatingapparatus:PDPsetmaybeoverheatedanddamaged. Thesetcanbeinstalledasshownbelow. Thesetcanbeinstalledonthewallasshownbelow. (Forfurtherinformation,refertotheoptional'MAINFRAMEInstallationandSetupGuide'.) (Forfurtherinformation,refertotheoptional'MAINFRAMEInstallationandSetupGuide'.) MAIN MAIN Hanger FRAME Hanger FRAME WALLBRACKET HangerBolt...
To prevent electric shock, Do not remove cover. No user serviceable part inside Refer servicing to qualified service personal. 100digit10digitsingledigit • Model Name : OPM-4250 • Voltage : AC~100 - 240V OUTPUT FCC Verified : Class "A" • Current : Max. 4A •...
MPDPisconnectedwithsuppliedRS-232Ccable. RS-232C DVI-D_2 M PDPOn/OfforScreenadjustmentcanbecontrolledbyMSCS(Multi-ScreenControl System). ID SELECT DVI-D_1 • Model Name : OPM-4250 • Voltage : AC~100 - 240V • Current : Max. 4A • Frequency : 50/60Hz • Serial No : I DsettingonthebacksideofMPDPmustbeidenticalwiththeIDsettinginMSCSto Made in Korea controlMPDPwithaPC.
Infinitely Expandable OPM-4250 | OPM-4250R 5.6. Multi-screen configuration 5.5. "new design/Last design" setting Input the numbers of X and Y WhenComPortissuccessfullyconnected,pop-upwindowfor"Newdesign/Lastdesign" X is for the number of row and Y is for column. appears. X and Y can be selected within the range from 1 to 15. The maximum MDPD quantity of MSCS control is 100 sets.
Infinitely Expandable OPM-4250 | OPM-4250R 5.9. input Select 5.7. MSCS instruction VarietiesofscreenformationsareavailablewithInputselectconfiguration. Check"ALLPDP"tosenddatatoallconnectedMPDPregardlessofID. SelectDVI1orDVI2attheInputSelectmenu. OnE PDP :TransmitProtocolCommandtooneMPDP. ALL PDP :TransmittheProtocolcommandsequentiallytoallconnectedMPDPsets. If you select DVI 2 and click Play button at the Input Select menu, the Broadcast :TransmittheProtocolcommandsimultaneouslytoallconnectedMPDPsets. input source will be changed from DVI 1 to DVI 2.
Page 19
Infinitely Expandable OPM-4250 | OPM-4250R Screen formation Screen Formation with one step. TomakevariousInput-screenformation,selectaninputsource(DVI1orDVI2)andclick Youcanmakevariousmulti-screenformationswithsimplemovement. thescreenyouwantintheScreenconfigurationwiththeleftbuttonofthemouse. Select an input source at Source Select menu. Select DVI 2 at the Input Select menu. e.g.) In case you want to select DVI 2 e.g.) in case DVI 2 is selected...
Infinitely Expandable OPM-4250 | OPM-4250R 5.10. Slide Control MPDPconfigurationthatuserscanchooseisdisplayedrepeatedly. TouseSlideControl,gotoMSCSMenu→Control→SlideControlorpress"Ctrl+S"using Save various screen configurations in the same way. Keyboard. DVI 1 DVI 2 DVI 2 DVI 1 DVI 2 DVI 2 DVI 1 DVI 2 DVI 2 Make a desirable configuration in "Screen Configurations"...
Infinitely Expandable OPM-4250 | OPM-4250R 5.11. Screen Control RegistervaluesrelatedtodisplayofMPDPcanbechanged. Click "Stop" button to end "Slide Control" TousePictureControl,gotoMSCSMenu→Control→PictureControlorpress"Ctrl+P" usingKeyboard. I nordertocontroldisplayvalues,inputvaluesdirectlyin"EditBox"andpressEnterkey. Orclick-/+buttonusingmouse. C lick"Exit"buttonorpress"Ctrl+X"usingkeyboardtoclose"PictureControl"window. Save or Load the slide configuration Color Temp :Changethecolortemperatureofthescreen Click "SAVE" button to save user added Slide configuration as "*.ssd" file.
Infinitely Expandable OPM-4250 | OPM-4250R How to Control BiC 1.MSCS 3. in case you want to use new MFC without using MSCS 1)MSCSandMPDPmustbealwaysconnected. 1) I fyouwanttousetheotherMPDPcontrolprogrambesidesMSCSandyoucannotintegrateBIC 2) I fMSCScommandisexecutedpriortotheBICcommand,theBICcommandwillbeexecutedagain controlprogramintotheMPDPcontrolprogram,youcanuseNewMFC. onehourlater. 2)ThenumbersofMPDPunitsshouldbesetbyNewMFC. 3)Turnofftheenergysavemodeofthecomputer. 3)TheNewMFCconnectedtoMPDPmustbealwaysturnedon. 4) T hecompensationforundesirableburn-ineffectismadeautomaticallywhenBICfunctionisexecuted. 4) D uringBICfunctionisbeingexecuted,allthecommandsareignored.Eventheremotecontrolleris Ifthecompensationresultisnotsatisfactory,useadditionalBurn-incompensationfunctioninMSCS....
Infinitely Expandable OPM-4250 | OPM-4250R 5.14. DVi Converter Vertical configuration TouseDVIConverter,gotoMSCSMenu→Device→DVIConverterorpress"Ctrl+V"using PressSETbutton. Keyboard. BROADCAST DVI 1 DVI 2 PressUpandDownbuttonssequentiallytoentertheverticalconfigurationmode. INFO INFO DVI CONVERTER INPUT HDMI VIDEO S-VIDEO HDSDI Whenthe2LEDsatlowerrightcornerofeach7-segmentoflowerlineinthe DVIC1 DVIC2 INFO AUTO OUTPUT FUNCTION MPDP NewMFCareturnedon,theverticalconfigurationmodeisstarted. REMOTE CONTROL UsethenumberbuttonstosetthenumbersofMPDPsetsinhorizontalline. - e .g.Ifyouwanttoset6forverticalnumber,press"0"forten'splaceand"6"...
Infinitely Expandable OPM-4250 | OPM-4250R 5.15. Orion PDP Home Page log on and Version information PiP( Picture in Picture ) AvarietyofimagescanbedisplayedwiththePIPfunctionofDVIconverter.Toactivate InordertomovetoOrionPDP'swebsite,goto"Help"ofmenubar→"OrionDisplay PIP,click"PIP"intheMode.Thepositionofsub-picturecanbecontrolledbyclicking-/+ HomePage". buttonsincreaseordecreasethenumberordirectlytypeinthenumbersatEditbox. Variousinputsourcescanbeused.Tosetthesub-input,clickthesub-inputcombobox andselectsub-input. Mainscreenandsub-screencanbeswappedwiththePIPSwapfunction.Press"Set" buttonattherightsideof"PIPSwap."Ifyouwanttoreturntopreviousscreen,press "Normal"buttonattherightsideof"PIPSwap." Mode : N ormalmode-NormalscreenwithoutPIP(PIPOff) OrionPDPHomePageLogon PIPmode-Sub-screenisdisplayedatthelowerrightcornerofthescreen.(PIPOn) Position : H orizontal-AdjustthehorizontallocationofPIP.Adjustablerange0~100 Vertical-AdjusttheverticallocationofPIP.Adjustablerange0~100...
Page 32
Infinitely Expandable OPM-4250 | OPM-4250R 3.3. Multi-Scale "Power On" Communication Sequence *Waitfor40msecforresponseaftersendingthecommand.Ifthereisnoresponse,itisrecommendedtoresendthecommand. *Itisrecommendedthatnotsendingtheothercommandorchanginginputresolutionduringcommandtransmission. Command for expanding the screen of MPDP. *Commandsequence:SlaveMaster.(ExceptforBroadcastcommand) It is available only on Power On (Operative) status. CMD: 0xDD (DVI 1), 0xEF (DVI 2) → Send to MPDP...
Page 33
Infinitely Expandable OPM-4250 | OPM-4250R 3.5. input-Mode Change "Multi-Scale" Communication Sequence *Waitfor40msecforresponseaftersendingthecommand.Ifthereisnoresponse,itisrecommendedtoresendthecommand. *Itisrecommendedthatnotsendingtheothercommandorchanginginputresolutionduringcommandtransmission. Command for changing input mode without screen scaling *Commandsequence:SlaveMaster. It is available only on Power On (Operative) status. CMD: 0x44 (DVI 1), 0xDC (DVI 2) → Send to MPDP...
Page 34
Infinitely Expandable OPM-4250 | OPM-4250R BroadcastCommand "Test Pattern" Communication Sequence *Waitfor40msecforresponseaftersendingthecommand.Ifthereisnoresponse,itisrecommendedtoresendthecommand. Length Data: ID *Itisrecommendedthatnotsendingtheothercommandorchanginginputresolutionduringcommandtransmission. Value 0x02 Variable 0x01 0x00 0x03 *Commandsequence:MasterSlave.(ExceptforBroadcastcommand) *MakeallPDP(Master/Slave)dothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand) → Test Pattern Command transmission (to Master) Test Pattern Response transmission (from Master) Receive from MPDP ←...
Page 35
Infinitely Expandable OPM-4250 | OPM-4250R 3.9. APL Control NormalCommand Data Length APL On/Soft/Off CMD: 0x54 (APL On), 0x55 (APL Soft), 0x56 (APL Off) Value 0x02 Variable 0x02 Variable Variable 0x03 It is available only on Power On (Operative) status. *IDrange(Program):0x01(1)~0xFF(255)
Page 36
Infinitely Expandable OPM-4250 | OPM-4250R 3.13. Default Data Load (Picture Control Data) *IDrange(Program):0x01(1)~0xFF(255) *M/S:SinceitisonlyMaster,"0x01"Valuemustbetransmitted. *CheckSum:Execute"Not"operationafteraddingallthevaluesin"STX~Data"area. Initialize the PDP set. All the settings will be returned to the initial condition prior to the adjustment in the factory. *ElapsedTime Pre-programmed value will be applied.
Page 37
Infinitely Expandable OPM-4250 | OPM-4250R 3.15. graphic User Mode Control "Get"commandfrom"Get/Set"in"Data"area Data Length Command for controlling Brightness, Contrast, Sharpness, Color and Tint Setting Values Value 0x02 0x6A 0x05 Variable Variable … 0x03 CMD: 0x8A (Brightness), 0x8B (Contrast), 0x8C (Sharpness) It is available only on Power On (Operative) status.
Page 38
Infinitely Expandable OPM-4250 | OPM-4250R Send to MPDP *Status(32byte) NormalCommand Explanation Data Length Data PWR Status 1 byte 0:PowerOff(Stand-by),1:PowerOn(Working) Length Value Input Source 1 byte 0x0C:PC,0x0E:DVI,0x0D:DTV,0x07:DVD,0x05:S-Video,0x02:Video Resolution 1 byte Value 0x02 Variable 0x03 Variable Variable Variable 0x03 Thevalueof"DisplayedResolutionatthetimeofdetection" BIC Mode...
Page 39
Infinitely Expandable OPM-4250 | OPM-4250R 3.19. Factory Data Load (Picture Control Data): Only Master "Get Current Status" Communication Sequence *Waitfor800msecforresponseaftersendingthecommand.Ifthereisnoresponse,itisrecommendedtoresendthecommand. *Itisrecommendedthatnotsendingtheothercommandorchanginginputresolutionduringcommandtransmission. Command for loading the Picure Control data (User Mode / White Balance / RGB Data / DTV Data / DVD Data / VIDEO Data) adjusted in the factory.
Infinitely Expandable OPM-4250 | OPM-4250R 3.22. Over-Temperature Shut-down Control : Only Master Receive from MPDP Data Length Check Sum Commands for automatic power off making MPDP set stand-by and OSD warning method, if IP board temperature is 95℃ or higher.
Infinitely Expandable OPM-4250 | OPM-4250R Other tips 7.2. About Plasma display panel 7.1. Before calling for service Thefollowingsarephenomenacausedbycharacteristicsoftheplasmadisplaypanel. Beforecallingforanyrepair,checkthefollowingandthenrefertoanearA/Scenter. Sinceitisnotafault,youmaycontinuetousetheproduct. ▶"Tick" sound from the main body. ▶Black or twinkling spots on the screen I fthereisnoproblemwiththescreenorsound,the"tick"soundislikelytoresultfrom Althoughtheplasmadisplaypanelismanufacturedwithhigh-precision thecabinetlightlyshrinkingwiththechangeofroomtemperature.Thesounddoes Caution technology,theremayexistblackortwinklingspotsonthescreen. notaffectproduct’sperformance.
Infinitely Expandable OPM-4250 | OPM-4250R Applicable DVi signals Specification WhenyouselectPCforinputsource,itdoesnotsupportDTVsignal. Model name OPM-4250 Power supply 100~240VAC.50/60Hz Resolution V-Freq. (Hz) H-Freq. (KHz) Remarks Average(Typical) 300W Power 640 x 480 31.46 VESA DMT consumption 360W Plasma display panel 800 x 600 30.99...