Installer Mode - Westinghouse WBRC 140W Series Installation Manual

Gas fired residential combi boiler
Table of Contents

Advertisement

Turn the dial
counterclockwise and clockwise to scroll through the displayed parameters. To view parameter details, press the
button at the appropriate screen. Press the
Press the
button again to return to Operation Mode.
To turn on Lock Mode, press the
Press the
button to save the selection and return to the parameters.
Press the
button again to return to Operation Mode.
NOTE: The Control System will not allow the changes if Lock Mode is activated. Lock Mode will have to be turned off before making
further changes.
Parameter
O: ot
A: Li or A: GA
b: It
C: Fr
d: Lc
E: oP
F: dH
H: Eh
I: St
J: oH
1: PH
2: rh
Burner Operation
L: rt
3: rH
Time
4: It
5: IH
Displays output condition for internal primary pump and
three way valve.
P: Ou
Table 22 – Status Mode Display Screen Descriptions
I. INSTALLER MODE
Installer Mode will activate when the
powered on, press the
Figure 45 – Installer Mode Screens
Toggle through items that can be viewed/changed by turning the dial
displayed items can be changed by turning the dial
button again to save settings.
To leave Installer Mode, press the
or
button at the d:Lc parameter. Turn the dial
Detail
Outdoor temperature
DHW Water flow rate
CH return water temperature
FAN speed (RPM)
Lock function (Lock)
CH supply temperature (Operating temperature)
DHW outlet temperature
Exhaust temperature
N/A
CH water overheat temperature
Supply power time
Burner operation time
Burner operation time
Ignition cycles
Ignition cycles
button is pressed and held for five seconds while the display is powered OFF. If the display is
button to turn it off before pressing and holding the
button again. The display will return to power off mode.
buttons to leave the parameter.
- Off
- On
. To view/change an item, press the
counterclockwise to lower and clockwise to raise the displayed value. Press the
counterclockwise or clockwise to scroll On or Off.
Description
Current outdoor sensor temperature
Current flow (Li: LPM, GA: GPM)
Current CH return water temperature
Current fan speed (RPM)
Lock Mode "ON"/"OFF"
Current CH supply temperature
Current DHW outlet temperature
Current exhaust temperature
Not Used (Default is 0)
Current temperature on the overheating sensor.
L:rt display on
sub menu
st
1
Icon
External Pump
Primary Pump
button for five seconds.
55
Unit : 100 hour
Unit : 1 hour
Unit : 1,000 hour
Cycle : 10 times
Cycle : 10,000 times
nd
rd
2
Icon
3
Icon
Internal
3 Way
Valve
button. Some
WHL-012 REV. 4.8.16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wbrc 199w series

Table of Contents