Operation Instructions - Crown EL-25 Installation & Operation Manual

Self generating steam jacketed kettles
Table of Contents

Advertisement

SELF GENERATING STEAM JACKETED KETTLES, MODELS EL AND EP

6.0 OPERATION INSTRUCTIONS

WARNING: The kettle and its parts are hot. Use care when
operating, cleaning and servicing the kettle.
Ensure that the external electrical service to kettle is on.
Check pressure gauge for correct cold kettle reading. Reading should be in the green area of
the gauge indicating 25 - 30 In. Hg (630 - 730 mm Hg) of vacuum. If reading is not low enough,
follow VENTING procedure in Troubleshooting section prior to using kettle.
Place power switch to ON position.
Preheat kettle by placing thermostat knob at '10' and wait until TEMPERATURE light goes off.
NOTE: Preheating should not be used when cooking milk and egg food
products which adhere to hot cooking surfaces. These foods should be
placed into kettle before heating has begun.
Add food to be cooked into kettle.
Place thermostat knob at required temperature setting from 1 to 10 coinciding with the following
table:
Part No. 10068R6
INSTALLATION AND OPERATION MANUAL,
10
2018-06-21