Engine Shutdown

During longer breaks in operation, the engine must be warmed up at least once every two weeks. This prevents
corrosion in the engine. If you expect the engine to remain unused for two months or more, it must be preserved:
Refer to the chapter Storage, page 82.
START
P0018811
42
OK
STOP

Before Engine Shutdown

Let the engine run at high idle (1500 or 1800rpm) for a
minimum of 5 minutes before the shutdown after
normal use. Normal use is defined as minimum 50%
load. After use with less than 50% load, high idle for
approximately 3 minutes is sufficient. This allows
engine temperature equalization and prevents boiling
once stopped and also allows the turbochargers to cool
down. This contributes to long, fault-free service life.
NOTICE! Do not turn off the main switch within 30
seconds after turning off the ignition. This is in order to
save engine data to the engine control unit.

Stop the Engine

CAUTION!
The EATS system needs time to for automatically
drainage and depressurizing.
Wait at least two minutes after the engine been turned
off before removing the AdBlue/DEF hoses.
1 Disengage the clutch, if possible.
2 Press the STOP button to turn off the engine.
3 Press the
button to turn off the ignition.

Auxiliary Stop

For location of the extra stop, refer to
Maintenance, page 56.
WARNING!
Working with or approaching a running engine is a
safety risk. Watch out for rotating components and hot
surfaces.
47710925 01-2019 © AB VOLVO PENTA