Section 3 - Environmental
3.1

Temperature and Humidity

The Display shall withstand operating and storage environmental conditions listed in Table 1.
Temperature
Relative
Humidity

Table 1. Temperature / Humidity Limits

Note 1:
Tair
≤32ºC : 95% RH maximum.
Tair
>32ºC : Absolute humidity content not to exceed 100% at 32ºC
Note 2:
Tair @ 20ºC < 48 hours
Tair @ 60º C < 168 hours
Note 3:
Background color changes slightly depending on ambient temperature
This phenomenon is reversible.
Note 4:
Tair @ -30ºC : 15% RH (exterior face of Vandal Shield)
Tair @ 54ºC : 100% RH (exterior face of Vandal Shield)
Note 5:
The LCD Panel is not warranted above 50ºC operating temperatures with a reduction in
MTBCF specified in Section 9.2.
Reference to "room ambient" is defined as 25ºC -30ºC [77ºF - 86ºF] and shall apply throughout this
specification unless otherwise noted.
This Display will not be subjected to environments outside of the limits of Table 1 for testing or any
other purpose.
3.2

Altitude

Maximum operating altitude shall be 3,000 meters [9,850 feet]. Maximum shipping and storage altitude
is 12,000 meters [39,400 feet].
3.3

Vibration and Shock

The packaged Display must comply to ASTM D4169,
Shipping Containers and Systems
3.3.1

Vibration (for non-packaged item)

The following Sections 3.3.1.1, 3.3.1.2, and 3.3.2 apply.
Title: Product Specification – LC08 High-Bright Monitor
Document Number: 023-0283-00
General Operating
Shipping and Storage
o
o
0
C to 60
C
o
o
[32
F to 140
F]
Note 1,4
. See Figure 3 below for orientation of axes.
Comments
o
o
-20
C to 60
C
o
o
[-4
F to 140
F]
Note 2,3,4,5
Note 1
Condensation
Standard Practice for Performance Testing of
Without
Page 8 of 26