8.4

System Transient Disturbance Requirements

The Display shall meet the following system transient disturbance requirements:
8.4.1

Electrostatic Discharge Requirements

The Display will perform normally when subjected to static electricity discharges from persons touching
the external surfaces of the Display. Performance is verified by testing according to EN 50082−1 (Ref IEC
801−2:1984) at severity level 3 (4 Kv contact discharge, 8 Kv air discharge). Tests are conducted with
service doors open. Testing is performed on points that are typically the first internal contact while
performing routing servicing and replenishment operations.
8.4.2

Electromagnetic Energy Susceptibility Requirements

The Display will perform normally in an electromagnetic field with a strength of 10-volts per meter from
10 KHz to 1 GHz. (REF CISPR 22).
8.5

Labeling

IEC 417 − Graphical Symbols for Use on Equipment.
8.6

Color Coding

ISO 3864 − Safety Colors and Safety Signs.