Electrical Connections; Relocate Control Panel To Right Side - Lincoln Electric Prism 4 Operator's Manual

Hide thumbs Also See for Prism 4:
Table of Contents

Advertisement

PRISM® 4

ELECTRICAL CONNECTIONS

Make all electrical connections compatible to your local city / state
code.
WARNING
ELECTRIC SHOCK can kill.
Only quali ed personnel should perform
this installation.
Turn the input power OFF and unplug the
machine from the receptacle before
working on this equipment.
Insulate yourself from the work and ground.
Always connect the Prism® 4 to a power supply
grounded according to the National Electrical Code and
local codes.
WARNING
All electrical wiring which includes primary, secondary
and control wiring must be done by certi ed/licensed
electrician.
ELECTROCUTION HAZARD.
Disconnect mains before servicing. Failure to do so
could result in serious personal injury or death.
Do not attempt installation of this unit unless you are
familiar with the necessary tools, equipment, utility
connections and potential hazards. Installation should be
performed only by a quali ed service provider. Failure to
do so could result in reduced performance of the unit,
serious personal injury or death.

RELOCATE CONTROL PANEL TO RIGHT SIDE

Review this manual for detailed instructions on the connection to
the control panel.
The control cabinet ships mounted on the left side as shown in
the unit illustrations. If required, it can be moved to the right side.
The control panel must be fully disconnected from input power
before performing these steps.
1. Drill holes in the right side dirty air panel. There are small
center marks in the panel marking location or just mirror the
left side holes to the right side. The holes required are: four
0.406" holes for the control panel and two 0.221" holes for
the smart wire module bracket.
2. Disconnect the fan motor cable from the control panel,
making sure to note wire color locations in the VFD.
3. Disconnect the green smart wire cable running from the smart
wire module above the compressed air tank to the smart wire
module next to the control panel.
4. Move the control panel and smart wire module to the right
side. The module bracket should be next to the door and the
module must be rotated 180° on the bracket so the "out"
port points towards the door.
5. Rotate the smart wire module above the compressed air tank
180° on the bracket so the "out" port points to the right.
6. Reroute the green cable from the module above the
compressed air tank to the module by the control panel. It
should route down the right side by the door.
7. If the fan's silencer needs to move due to obstruction, the fan
can be rotated but it is not required. If rotating the fan, the
motor assembly needs to be rotated on the fan housing so
the motor's connection box is on the back. The motor
assembly can be rotated on the fan housing by removing the
bolts on top of the fan housing.
8. Reroute the fan motor cable down the right rear of the unit
and reconnect it to the control panel's VFD. Make sure to
connect the proper color wire to its original location.
9. The air regulator can be moved to the right side also, but
the compressed air tank's end ttings will need to be
swapped.
NOTE: The open holes on the left side panel must be plugged.
Bolts and nuts work well - 3/8-16 at the control panel location
and 1/4-20 at the module bracket location.
A-7
INSTALLATION