Technical data
For details of the rated voltage, current, frequency and/or input power, please refer to the power tool's
country-specific type identification plate.
When powered by a generator or transformer, the generator or transformer's power output must be at least
twice the rated input power shown on the rating plate of the power tool. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the power tool.
Weight in accordance with EPTA procedure 01
Single impact energy in accordance with EPTA procedure 05
Hammer drill bits, Ø
Ø drill bits for wood
Ø drill bits for metal
4.1
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the power tool is switched
off, or when it is running but not actually being used for a job. This can significantly reduce exposure over
the total working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise emission values
Sound (power) level (L
WA
Uncertainty for the sound power level
(K
)
WA
Emission sound pressure level (L
Uncertainty for the sound pressure level
(K
)
pA
Total vibration
Hammer drilling in concrete (a
Chiseling (a
)
h,Cheq
Uncertainty (K)
5
Operation
5.1
Fitting the side handle
CAUTION
Risk of injury Loss of control over the product.
▶ Check that the side handle is fitted correctly and tightened securely. Check that the clamping band is
engaged in the groove in the product.
▶ Fit the side handle.
*2063038*
TE 70­AVR
)
113 dB(A)
3 dB(A)
)
99 dB(A)
pA
3 dB(A)
TE 70­AVR
)
10.8 m/s²
h, HD
9 m/s²
1.5 m/s²
2
2063038
TE 70­AVR
8.3 kg
11.5 J
12 mm ... 55 mm
10 mm ... 32 mm
0 mm ... 20 mm