Venting Installation - Superior Fireplaces Superior Pro Series Installation And Operation Instruction Manual

Wood-burning fireplaces
Table of Contents

Advertisement

FIREPLACE INSTALLATION Continued
FAN/BLOWER KIT ASSEMBLY (FOR CIRCULATING MODELS ONLY)
Fan or blower kit is optional with this fireplace (for circulating mod-
els only). Use of blowers or fans other than those manufactured
by IHP voids warranty. Blower is operated by turning control knob
(not shown).
Fan/blower kit electrical connections are made through electrical
cover plate on side of fireplace a shown in Figure 7.
Electrical
Wire Nut (3x)
Housing
(Not Supplied)
Receptacle
(Supplied)
Prewired Receptacle
and Ground
Figure 7 - Fan Switch-Electrical Bushing
Wiring Instructions
1. Remove electrical cover plate with bushing from fireplace by
removing 2 sheet metal screws as shown in Figure 7.
2. Slide power source wiring through electrical bushing opening
and electrical cover plate and make all necessary connections.
3. Slide all wiring connections in electrical housing as shown in
Figure 7.
4. Secure electrical cover plate with screws previously removed.
Note: Electrical housing and cover plate have sharp edges. Wear
protective gloves.
126622-01_L
Sheet
Metal
Screws
Electrical
Electrical
Cover Plate
Bushing
Outer Wrapper
of Fireplace
Power Source Wiring
(Not Supplied)
To Power
Source
Electrical Cover
Plate and Electrical
Bushing
Fireplace
Chassis Ground
SuperiorFireplaces.us.com

VENTING INSTALLATION

OPTIONAL OUTSIDE AIR KIT (MODEL AK4/AK4F)
Installation of outside air kit should be performed during rough fram-
ing of fireplace due to the nature of it's location. Outside combustion
air is accessed through a vented crawl space (AK4F) or through a
sidewall (AK4). See page 14 for instructions of operating air kit.
CAUTION: Combustion air inlet ducts shall not
terminate in attic or garage space.
The maximum height for the air vent can not exceed
3 feet below the flue gas outlet of the termination.
Secure to Collars with Metal Tape, Screws
or Straps (Min. of 1/4" x 20" in size)
Air Inlet
Location
Must Allow
For Bushes
or Snow
Vented Crawl Space (Check
Local Codes Before Installing
in a Vented Crawl Space)
Figure 8 - Outside Air Kit
CHIMNEY PIPE
WARNING: Label part number 900599-01 must
be applied by the installer to all chimney pipe
sections but is not required on sections that will
be visible after the installation is complete. Label
must wrap around the circumference of the pipe.
See accessories, page 20 for Kit F2659.
An IHP chimney system consists of 12", 18", 24", 36" and 48" snap-
lock, double-wall pipe segments, planned for maximum adaptability
to individual site requirements. Actual lengths gained after fitting
overlaps must be taken into consideration (lineal gain) and are given
in lineal gain chart (see Figure 9, page 8).
Lineal gain is actual measurable length of a part after two or more
parts are connected.
Air Inlet
Vent Hood
Eyebrow
Required
for Wall
Installation
7