This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also
contains information that will enable you to obtain replacement parts or accessory items when needed. Keep
it with your other important papers.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This wood burning fireplace complies with UL127
CAN/ULC-S610-M87 standard as a FACTORY
BUILT FIREPLACE.
This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANSI Z21.60
or Z21.84 standards or for use with a vent-free gas log heater approved to ANSI Z21.11.2 standard. An INNOVATIVE
HEARTH PRODUCTS, LLC hood must be installed when using a vent-free log heater (see Accessories, page 19).
FOR CANADA: The authority having jurisdiction
(such as the municipal building department, fire
department, etc.) should be contacted before
installation to determine the need to obtain a permit.
These models meet the EPA Wood Burning Fireplace Program Phase 2 emission level. NOTE: To ensure proper
fireplace operation, the catalyst should be replaced at a minimum of 3 years and a maximum of 5 years.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
INSTALLATION AND OPERATION INSTRUCTIONS
Superior™ Pro Series Cat Wood burning
Fireplaces
PFS
®
C
US
REPORT NO. 10-078
SAVE THIS BOOK
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
Ce foyer au bois est conforme aux UL 127 CAN/ULC-
S610-M87 norme comme une USINE CONSTRUITE
CHEMINÉE.
POUR LE CANADA: L'autorité compétente (comme le
service municipal du bâtiment, les pompiers, etc.) doit
être contacté avant l'installation afin de déterminer la
nécessité d'obtenir un permis.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utilizer d'essence ni d'autres
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
— L'installation et l'entretien doivent être assurés par un
For more information, visit Superiorfireplaces.US.com
MODELS
WRT3836RS
WCT3836RS
WRT3836RSI
WCT3836RSI
WRT3836RH
WCT3836RH
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment
où vous trouvez.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
installateur ou un service d'entretien qualifié ou par
le fournisseur de gaz.
WRT3836WS
WCT3836WS
WRT3836WSI
WCT3836WSI
WRT3836HWS
WCT3836HWS

Advertisement

Table of Contents
loading

Summary of Contents for Superior Fireplaces WRT3836RS

  • Page 1 INSTALLATION AND OPERATION INSTRUCTIONS Superior™ Pro Series Cat Wood burning Fireplaces MODELS ® WRT3836RS WCT3836RS WRT3836WS WCT3836WS P126625 01 WRT3836RSI WCT3836RSI WRT3836WSI WCT3836WSI P/N 126625-01 Rev. D 05/20/15 REPORT NO. 10-078 WRT3836RH WCT3836RH WRT3836HWS WCT3836HWS SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed.
  • Page 2: Table Of Contents

    Thank you for your purchase. We appreciate your TABLE OF CONTENTS business! Safety .....................2 Please carefully read and follow all instructions in this manual. Pay Specifications .................4 special attention to all warnings and safety information. Fireplace Installation ..............5 Following these safety, care, and operation instructions will help Venting Installation ................7 ensure many years of dependable and enjoyable service from your PureFire Hood Installation ............13...
  • Page 3 SAFETY Continued WARNING: CONTINUED OVERFIRING CAN PER- WARNING: BURNING IMPROPER FUEL (I.E. MANENTLY DAMAGE YOUR FIREPLACE SYSTEM. CHARCOAL) CAN RESULT IN CARBON MONOXIDE SOME EXAMPLES OF CONDITIONS THAT COULD POISONING, WHICH MAY LEAD TO DEATH! CAUSE OVERFIRING ARE: Carbon Monoxide Poisoning – Early signs of carbon monoxide poisoning resemble the flu with headaches, • BURNING QUANTITIES OF SCRAP LUMBER, PINE BRANCHES, PAPER OR CARDBOARD BOXES...
  • Page 4: Specifications

    SPECIFICATIONS GAS LINE RIGHT SIDE KNOCK ELECTRICAL OUTLET OUTS 1" AIRSPACE TO COMBUSTIBLE MATERIAL 0" TO NO COMBUSTIBLE " MATERIAL ON FACE " SPACERS " " AIR KIT " KNOCK OUT LEFT SIDE GAS LINE KNOCK COMBUSTIBLE OUTS WALL BOARD "...
  • Page 5: Fireplace Installation

    FIREPLACE INSTALLATION SELECTING LOCATION To determine safest and most efficient location for fireplace, you must take into consideration the following guidelines: 1. Location must allow for proper clearances (see Figures 1 and 2). 2. Consider a location where fireplace will not be affected by drafts, air conditioning ducts, windows or doors.
  • Page 6 FIREPLACE INSTALLATION Continued *Note: Drawing Not To Scale WARNING: Hearth extension is to be installed Combustible " Ref. only as shown in Figure 3. Material Safe Zone For 6" Projection of Seal Gap Ref. Combustible Fireplace Front 33° Materials Non Combustible 3"...
  • Page 7: Venting Installation

    VENTING INSTALLATION OPTIONAL OUTSIDE AIR KIT (MODEL AK4/AK4F) WARNING: The opening in collar around chimney at top of fireplace must not be obstructed. Never use Installation of outside air kit should be performed during rough fram- ing of fireplace due to the nature of it's location. Outside combustion blown insulation to fill chimney enclosure air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4).
  • Page 8 VENTING INSTALLATION Continued ASSEMBLY AND INSTALLATION OF DOUBLE WALL CHIMNEY Continue to assemble chimney sections as outlined, making sure SYSTEM that both inner and outer pipe sections are locked together. When installing double wall snap-lock chimney together, it is important to Each double wall chimney section consists of a galvanized outer assure joint between chimney sections is locked.
  • Page 9 VENTING INSTALLATION Continued See Detail A Ceiling Support Pipe 12S-8DM 2" Min. See Detail B Straps Straps Straps Straps Detail B Detail A Angle Return Elbow Firestop Figure 9 - Ceiling Support Pipe 12S-8DM OFFSET RISE CHIMNEY LENGTH 48" 36" 24" 18" 12" "...
  • Page 10 VENTING INSTALLATION Continued FIRESTOP SPACERS (3600FS-8DM-1) Minimum Measurements " Firestop spacers are required at each point where chimney penetrates (36.5 cm) a floor space. Their purpose is to establish and maintain required 30" 1" clearance between chimney and combustible materials. When pipe (76.2 cm) (2.5 passes through a framed opening into a living space above, firestop...
  • Page 11 VENTING INSTALLATION Continued Storm Collar Installation (SC1) CAUTION: Do not seal openings on the rooftop Place storm collar over pipe and slide down until it is snug against flashing. Follow the installation instructions provided open edge of flashing (see Figure 15). Use SC1 for all round termina- tions.
  • Page 12 VENTING INSTALLATION Continued CHASE INSTALLATIONS Level of Flue Gas Instructions for chase installations are included with chase style ter- Outlet mination chosen. In a multiple chase installation, be sure to provide adequate distance between terminations to prevent smoke spillage 2' Min. from one termination to another.
  • Page 13: Purefire Hood Installation

    PUREFIRE HOOD INSTALLATION Hood The PureFire hood supplied with this fireplace is packaged in a separate box and placed in the firebox during shipping. Remove hood from box. Lift the hood up into the fireplace at an angle with the rear facing Refractory up.
  • Page 14: Operation And Maintenance

    OPERATION AND MAINTENANCE Continued OPTIONAL GAS LINE INSTALLATION Continued " WARNING: FIREPLACES EQUIPPED WITH DOORS WARNING: Do not operate an unvented gas log SHOULD BE OPERATED ONLY WITH DOORS FULLY set in this fireplace with chimney removed. OPEN OR DOORS FULLY CLOSED. IF DOORS ARE LEFT If you install a decorative gas appliance (vented gas log), decorative PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT gas appliance must comply with the Standard for Decorative Gas...
  • Page 15: Purefire Emissions Control System

    Fireplaces with lower emissions produce less smoke when installed and operated properly. MANUFACTURER: INNOVATIVE HEARTH PRODUCTS, LLC MODEL NO: WRT3836RS 36" Woodburning Fireplace WRT3836WS 36" Woodburning Fireplace PARTICLE EMISSIONS: 4.8 GRAMS/KG OF WOOD BURNED For proper operation, catalyst must be replaced every 3 to 5 years.
  • Page 16: Replacement Parts List

    REPLACEMENT PARTS LIST WOOD BURNING FIREPLACE MODELS: MODEL CATALOG NO. WRT3836RS F0671 WRT3836RSI F0672 WRT3836RH F0673 WCT3836RS F0674 WCT3836RSI F0675 WCT3836RH F0676 WRT3836WS F0677 WRT3836WSI F0678 WRT3836HWS F0679 WCT3836WS F0680 WCT3836WSI F0681 WCT3836HWS F0682 36/37 Superiorfireplaces.US.com 126625-01D...
  • Page 17 This list contains replaceable parts used in your fireplace. WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. WRT3836RS WCT3836RS WRT3836RSI...
  • Page 18 WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. HERRINGBONE LINER STACKED LINER MODEL CATALOG NO. WRT3836RS F0671 WRT3836RSI F0672 WRT3836RH F0673...
  • Page 19: Accessories

    ACCESSORIES CAT NO. MODEL DESCRIPTION BI-FOLD GLASS DOORS F0981 BD36 36" Standard Bi-Fold Glass Door - Black finish F0982 BD36B 36" Standard Bi-Fold Glass Door - Brushed Brass finish F0983 BD36P 36" Standard Bi-Fold Glass Door - Platinum finish DOUBLE WALL PIPE F0895 12-8DM 12"...
  • Page 20 ACCESSORIES Continued ANTI-DRAFT SHIELD (Round Top Termination Only) F0927 ADS-8DM Anti-Draft Shield for Round Top Only MESH ROUND TOP TERMINATIONS F0916 RT-8DM Round Top with Mesh Screen F0888 RT-8HT Hi-Temp Round Top with Mesh Screen RTL-8DM Round Top Termination 8" RTL-8HT Hi-Temp Round Top Termination LG.
  • Page 21 ACCESSORIES Continued IMPORTANT NOTICE NOTICE: The firebox canopy (hood) Canadian code CAN/ULC-S610-M87 and other pertinent A manufactured shroud which codes require stainless steel chimney for the installation must not be modified or replaced with of this fireplace. A Cold Air Climate Kit is also required has been approved by a na- a canopy that may be provided with in Canada and is recommended for cooler regions in the...
  • Page 22: Replacement Parts

    REPLACEMENT PARTS TECHNICAL SERVICE See Pages 16 to 18 for a complete replacement parts list. Use only You may have further questions about installation, operation, or parts supplied from the manufacturer. troubleshooting. Please contact your IHP dealer for any questions or concerns.
  • Page 23: Warranty

    Innovative Hearth Products Superior™ Brand Wood-Burning Fireplace 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand wood burning fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 24 WARRANTY KEEP THIS WARRANTY Model Number Serial Number Date Installed Dealer's Name Dealer's Phone Number Keep receipt for warranty verification IHP reserves the right to make changes at any time, without notice, in design, materials, specifica- tions, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.

Table of Contents