Operation And Maintenance - Superior Fireplaces Superior Pro Series Installation And Operation Instruction Manual

Wood-burning fireplaces
Table of Contents

Advertisement

GLASS DOORS
Glass doors are optional with this fireplace. When fireplace is in
operation, doors must be fully opened or fully closed position only
or a fire hazard may be created (see Figure 24).
A fireplace equipped with glass doors operates much differently than
a fireplace with an open front. A fireplace with glass doors has a
limited amount of air for combustion. Excessive heat within fireplace
can result if too large a fire is built or if combustion air gate is not
completely open.
The following tips should be used to assure that both fireplace and
glass door retain their beauty and function properly. Both the flue
damper and glass doors must be fully opened before starting a
fire. This will provide sufficient combustion air and maintain safe
temperatures in firebox.
IMPORTANT: The glass must be allowed to warm slowly and evenly.
Tempered glass will withstand a gradual temperature rise to 550°
F, which is more than a normal fire will generate. Such materials as
pitch/wax laden logs, very dry mill end lumber and large amounts
of paper or cardboard boxes can create an excessively hot fire and
should not be burned in this fireplace. Always keep fire back from
doors and never allow flames to contact glass.
WARNING: FIREPLACES EQUIPPED WITH DOORS
SHOULD BE OPERATED ONLY WITH DOORS FULLY
OPEN OR DOORS FULLY CLOSED. IF DOORS ARE LEFT
PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT
OF THE FIREPLACE OPENING, CREATING RISKS OF
BOTH FIRE AND SMOKE.
WARNING: Discontinue use of the appliance imme-
diately if doors are damaged and contact a qualified
installer for repair. Only doors certified with the
appliance shall be used.
WARNING: Do not slam or strike doors. Damage
can result in a hazardous condition.
Doors Fully Closed
Fireplace Front
Doors Fully Opened
Fireplace Front
Figure 24 - Glass Doors
14

OPERATION AND MAINTENANCE

Cleaning Glass
Clean glass with any commercial glass cleaner or soap and water.
Do not use any abrasive material to clean the glass. Do not clean
glass with any cool water if glass is still hot from fire and smoke.
WARNING: Risk of fire! Replace grate with IHP
cat. no. J4382 only. This grate has been designed to
keep the operation of your fireplace safe and efficient.
OUTSIDE AIR AND DAMPER HANDLE OPERATION
The damper handle, which opens and closes the damper blade, is
located in upper front face of fireplace. Pushing handle into the left
of keyway slot will free damper blade to automatically open. Pushing
handle into the right will lock damper blade closed (see Figure 25).
Outside air kit handle is located at left hand side of fireplace (see
Figure 25). Pulling handle out will free outside air door to open.
Pushing handle in will lock door closed.
Outside Air
Kit Handle
LOCATING ACCESS COVER PLATE
Sheet metal cover plates located underneath front hearth refractory
may have shifted or moved out of place while fireplace was in transit.
These cover plates must be kept in the proper location prior to using
the fireplace (See Figure 26).
For further operating guidelines, instructions and warranty informa-
tion, please refer to your homeowner's guide or contact your dealer.
SuperiorFireplaces.us.com
Damper Handle
Handle Retainer
Figure 25 - Damper and Air Kit Handle
Access Panel
Figure 26 - Locating Access Cover Plate
Keyway Slot
126622-01_L