Venting Installation - Superior Fireplaces WRT3836RS Installation And Operation Instruction Manual

Cat wood burning fireplaces
Table of Contents

Advertisement

OPTIONAL OUTSIDE AIR KIT (MODEL AK4/AK4F)
Installation of outside air kit should be performed during rough fram-
ing of fireplace due to the nature of it's location. Outside combustion
air is accessed through a vented crawl space (AK4F) or through a
sidewall (AK4). See Figure 6 for instruction of operating air kit.
CAUTION: Combustion air inlet ducts shall not
terminate in attic space.
The maximum height for the air vent can not exceed
3 feet below the flue gas outlet of the termination.
Secure to Collars with Metal Tape, Screws
or Straps (Min. of 1/4" x 20" in size)
Air Inlet
Location
Must Allow
For Bushes
or Snow
Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)
Figure 6 - Outside Air Kit
CHIMNEY PIPE
An IHP chimney system consists of 12", 18", 24", 36" and 48" snap-
lock, double-wall pipe segments, planned for maximum adaptability
to individual site requirements. Actual lengths gained after fitting
overlaps must be taken into consideration (lineal gain) and are given
in lineal gain chart (see Figure 7).
Lineal gain is actual measurable length of a part after two or more
parts are connected. For Canada, use chimney parts designated "HT".
126625-01D

VENTING INSTALLATION

Air Inlet
Vent Hood
Eyebrow
Required for
Wall Installation
Superiorfireplaces.US.com
WARNING: The opening in collar around chimney
at top of fireplace must not be obstructed. Never use
blown insulation to fill chimney enclosure
12
/
"
3
8
Galvanized
Outer Pipe
8" Stainless
Inner Pipe
LINEAL GAIN
CAT. NO.
PART NO.
DESCRIPTION
36"
Fireplace
F0895
12-8DM
Pipe Section
F0881
12-8HT
F0896
18-8DM
Pipe Section
F0882
18-8HT
F0897
24-8DM
Pipe Section
F0883
24-8HT
F0898
36-8DM
Pipe Section
F0884
36-8HT
F0899
48-8DM
Pipe Section
F0885
48-8HT
F0916
RT-8DM
Round Termination
RTL-8DM
Round Termination
F0918
RLT-8DM
Round Termination
Round Termination with
F0917
RTT-8DM
Slip Section
Round Termination with
RTTL-8DM
Slip Section
Round Termination with
F0919
RLTT-8DM
Slip Section
F0920
ET-8DM
Square Chase-Top
Square Chase-Top with
F0922
ETO-8DM
Mesh
Square Chase-Top with
F0921
ETL-8DM
Slip Section
Square Chase-Top with
F0923
ETLO-8DM
Mesh & Slip Section
* The lineal gain for the terminations is measured to the
flue gas outlet height.
Figure 7 - Lineal Gain
.
Hemmed
End
GAIN
37
/
"
1
2
10
/
"
5
8
16
/
"
5
8
23
/
"
5
8
34
/
"
5
8
46
/
"
5
8
6
/
"*
7
8
7
/
"*
3
4
7
/
"*
1
2
6
/
" to
7
8
23
/
"*
1
8
8
/
" to
1
2
21
/
"*
1
2
7
/
" to
1
2
21
/
"*
1
4
12"*
12"*
7" to 15"*
12" to
25
/
"*
1
2
7

Advertisement

Table of Contents
loading

Table of Contents