Installation
(continued)
Optional Leg Accessory Installation
CAUTION!
Use caution when tipping the dispenser during leg installation.
Do not lay unit on back or side. DO NOT EXCEED 30° angle.
Tipping more than 30° can result in compressor malfunction.
1. If installing optional 4" (10.16 cm) Leg Accessory (item#
00956300), place a 12.7 cm (5") spacer underneath the
dispenser to ease installation.
2. Remove four plastic, thread-protecting plugs from bottom of
dispenser.
3. Screw each leg into chassis (Fig. 3).
Freestanding Installation
Installation instructions for countertop model may be found on
page 7.
1. A clearance of at least 77 mm (3") is required behind and
on each side of the dispenser for electrical connection and
ventilation (Fig. 1).
2. Rough-in the electrical service and water line.
§ Electrical: 230V, single phase. The dispenser is provided with an
2.4 m (8 ft.) power cord with choice of CEE 7/7, AS 3112, or BS
1363 plug.
§ Water: supply line (with shut-off valve) connects to the dispenser's
1/4" MPT inlet.
NOTICE!
If installing optional Leg Accessory, complete those steps
before proceeding. See
instructions.
8
Dispenser and Ice machine E7CI100A/E7FS100A
–––––––––––––––––––––––––––––––––––––––––––––––
page 10
for Leg Accessory
Fig. 3
spacer
12.7 cm (5")
min.
Fig. 4
freestanding models
minimum 77 mm (3")
clearance required