VK / TR SERIES GAS FRYERS
6. When fry tank is empty turn on the filter pump by pressing the filter button on the (A)
control or by holding your finger on the filter icon for 3-4 seconds on the solid state digital
models (D) and for computer models (C). Allow the pump to filer the oil for a couple of
minutes BEFORE closing the drain valve.
7. Close the drain valve. The display will change to; FILL TANK for solid state digital models
(D) and FILL TANK for computer models (C).
8. Fill tank with new shortening. Fill to a minimum of the MIN level but no higher than halfway
between MIN and MAX. Oil will expand as it is heated.
9. On solid state digital models (D) and computer models (C) models, the display will ask if
the tank is full; TANK FULL, HIT TEMP. If the tank is full, press the Temp Button on the
display. Once pressed, the gas power burner will ignite and begin heating the oil to desired
temperature.
10. Press the START button for solid state knob control (A) and gas power burner with ignite
and begin heating the oil.
VULCAN-HART
-22-
F-32971 Rev. M (June 2013)