Graco 257025 Operation page 4

Hide thumbs Also See for 257025:
Table of Contents

Advertisement

*Call AAA Rent-All at 225-291-1356 for assistance ordering parts*
Warnings
SKIN INJECTION HAZARD
High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event
that injection occurs, get immediate surgical treatment.
Do not aim the gun at, or spray any person or animal.
Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with
any part of the body.
Always use the nozzle tip guard. Do not spray without nozzle tip guard in place.
Use Graco nozzle tips.
Use caution when cleaning and changing nozzle tips. In the case where the nozzle tip clogs while
spraying, follow the Pressure Relief Procedure for turning off the unit and relieving the pressure
before removing the nozzle tip to clean.
Equipment maintains pressure after power is shut off. Do not leave the equipment energized or under
pressure while unattended. Follow the Pressure Relief Procedure when the equipment is unat-
tended or not in use, and before servicing, cleaning, or removing parts.
Check hoses and parts for signs of damage. Replace any damaged hoses or parts.
This system is capable of producing 3000 psi. Use Graco replacement parts or accessories that are
rated a minimum of 3000 psi.
Always engage the trigger lock when not spraying. Verify the trigger lock is functioning properly.
Verify that all connections are secure before operating the unit.
Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar with the controls.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
Always wear appropriate gloves, eye protection, and a respirator or mask when painting.
Do not operate or spray near children. Keep children away from equipment at all times.
Do not overreach or stand on an unstable support. Keep effective footing and balance at all times.
Stay alert and watch what you are doing.
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not kink or over-bend the hose.
Do not expose the hose to temperatures or to pressures in excess of those specified by Graco.
Do not use the hose as a strength member to pull or lift the equipment.
Do not spray with a hose shorter than 25 feet.
Do not alter or modify equipment. Alterations or modifications may void agency approvals and create
safety hazards.
Make sure all equipment is rated and approved for the equipment in which you are using it.
PRESSURIZED ALUMINUM PARTS HAZARD
Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical
reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or prop-
erty damage.
Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or flu-
ids containing such solvents.
Do not use chlorine bleach.
Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier
for compatibility.
4
WARNING
WARNING
WARNING
3A0248E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Project painter plus

Table of Contents