Setup
1. Make sure the power switch is OFF and the sprayer
is unplugged.
ti2810a
2. Separate prime tube (smaller) from suction tube
(larger).
3. Place prime tube in waste pail.
WASTE
4. Submerge suction tube in water or flushing solvent.
WATER
ti14963a
5. Lift prime/spray valve to PRIME.
ti13961a
6. Plug sprayer in a grounded outlet.
7. Turn power switch ON.
ti5580a
8. Align setting indicator with prime/clean setting on
pressure control knob until pump starts, page 10.
12
ti2039a
ti14962a
ti12948a
9. When sprayer starts pumping, flushing solvent and
air bubbles will be purged from system. Allow fluid
to flow out of prime tube, into waste pail, for 30 to 60
seconds.
10. Turn power switch OFF.
ti2810a
11. Transfer suction tube to paint pail and submerge
suction tube in paint.
PAINT
12. Turn power switch ON.
ti5580a
13. When you see paint coming out of prime tube:
a. Point gun into waste pail.
b. Unlock gun trigger lock.
ti8909a
c. Pull and hold gun trigger.
d. Lower Prime/Spray valve to SPRAY.
ti14963a
ti13960a
3A0248E